Download Print this page

Farfisa ZHeroS Manual page 16

Hands free colour video intercom for duo digital system

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13
- Programming Actuator Address:
with microswitches SW1 set the actuator address that it is
intended to control (from 211 to 230) and with microswitches
SW2 set the room number 0 (see table on page 39);
press for a long time key
occurred storing.
To change the stored address, it is necessary to set with
SW1 and SW2 the new codes and press for a long time key
until a tone will confirm the occurred storing; instead
to delete the stored address, it is necessary to set code
255 on SW1 and 0 on SW2 (see table on page 39) and
press for a long time key
occurred cancellation.
4.1.4 Forwarding a floor call
Upon arrival of a call from a floor, only the monitor to which
the call pushbutton is connected rings. If it is intended to
relaunch the call also on all the other monitors present in
the apartment or in another apartment, it is necessary to
proceed as follows:
- with microswitches SW1 set the address of the main
video intercom of the apartment to which it is intended to
forward the floor call and with microswitches SW2 set the
room number 0 (see table on page 39); press for a long
time key
until a tone will confirm the occurred storing.
Attention: when forwarding a floor call, all video
intercoms (both main and secondary) present in the
apartment to which the floor call was forwarded will
ring.
To change the stored address, it is necessary to set with
SW1 and SW2 the new codes and press for a long time key
until a tone will confirm the occurred storing; instead, to
delete the stored address, it is necessary to set code 255
on SW1 and 0 on SW2 (see table on page 39) and press
for a long time key
until a tone will confirm the occurred
cancellation.
4.1.5 Additional Addresses
A video intercom can be enabled to receive also the calls
addressed to other users (max 4); for the programming of
the relative addresses it is necessary to proceed as follows:
- with microswitches SW1 set the address of the first user
for whom it is desired to answer and with microswitches
SW2 the relative room number (see table on page 39);
press for a long time key
occurred storing of the first address. If it is intended to
programme other additional addresses, it is necessary to
set microswitches SW1 with the address of the second
user for which it is desired to answer and microswitches
SW2 with the relative number of room (see table on page
39); press for a long time key
the occurred storing of the second address. Proceed in
a similar way for the programming of the address of the
third and fourth user for which it is desired to answer; the
occurred programming is confirmed respectively by three
or four tones.
To change the stored addresses, it is necessary to exit
from the programming, wait 3 seconds and re-enter into
the programming; set with SW1 and SW2 the new codes
and press for a long time key
the occurred storing of the new first additional address;
proceed in a similar way to change the eventual second,
until a tone will confirm the
until a tone will confirm the
until a tone will confirm the
until two tones will confirm
until a tone will confirm
third and fourth address. To delete stored addresses, it is
necessary to set code 255 on SW1 and 0 on SW2 (see table
on page 39) and press for a long time key
will confirm the occurred cancellation of the first address;
proceed in a similar manner to cancel any second, third
and fourth stored address.
4.1.6 Exit from the system programming
To exit from programming, jumper J4 must be taken from
position 1-2 to position 3-4, icon
4.1.7 Restore factory settings
To restore default factory settings, you must:
- Access programming mode (see section 4.1.1);
- Press in sequence keys
- the
icon flashes for 1 second and the
OFF, the device settings and system programming are
returned to the default factory settings;
- exit the programming mode (see section 4.1.6).
4.2 Video intercom programming
For programming of the device it is necessary to set the
codes that identify the video intercom respectively inside
the plant (user addresses from 001 to 200) and inside the
apartment (room number from 0 to 3).
For user address keep in mind that:
- it must not be the same number of another apartment;
if more internal stations in parallel are in the apartment,
they must have the same user address but different
room number (see next paragraph);
- it must coincide with the number stored in the external
keyboard and in the possible reception switchboard;
- it must be stored in the key call or in the device contacts of
another user if it is necessary to intercommunicate between
the two apartments.
For the number of room, keep in mind that:
- the number of room establishes also a hierarchy in the
internal device, as the device that will have room number
0 (zero) will be defined as the main, while all others will
be secondary;
- the different number of room allows carrying out and
selectively receiving calls between devices within the same
apartment; the calls from outside or from another apartment
will ring up all the devices, the first to answer will activate
the conversation and will turn off the ringtones of the others;
- upon arrival of a call from an external video intercom station,
all the devices will ring, but only the main (number of room
0 "zero") shows the image of the camera. From the other
video intercoms of the same apartment, it is possible to view
the entry by pressing key
ringtones, turns on the video intercom and simultaneously
turns off the main video intercom.
4.2.1 User Address and number of room.
To program the address and the room number of the video
intercom no procedure is needed, just place microswitches
SW1 and SW2 in accordance with the table on page 39;
(from factory the video intercom is programmed with user
address 100 and room number 0).
Attention: since microswitches SW1 and SW2 are used
to perform also other programming (see paragraph 4.1
System Programming), their position may have been
changed.
before using the device remember to position
microswitches SW1 and SW2 in accordance with
- 16 -
until a tone
will turn off.
;
icon turns
. This operation deactivates all
Mi 2567