Command
ID 46 27 DD 00 (CRC)
ID
Syntax
46
Description
27
DD
00
Response
ID 46 27 00(CRC)
ID C6 00 (CRC)
Example:
Send Command:"01 46 27 01 00".......Set up TRP-C29U's power on value.
Response:"01 46 27 00"...Command valid.
Error Response: "01 C6 00"......Error code.
Then send "01 46 09 00" ........After reset will get power on DD value
10-12.Read power on mode value
Command
ID 46 28 00 (CRC)
ID
Syntax
46
Description
28
00
Response
ID 46 28 DD (CRC)
ID C6 00 (CRC)
Example:
Send Command:"01 46 28 00".......Read TRP-C29U's power on value.
Response:"01 46 28 08 "...Power on DO status DO7~DO0 is "00010011".
Error Response: "01 C6 00"......Error code.
*Power on mode: Digital output states when power on.
Address of setting module 1~247
Function Code
Set up power on mode
Digital output power on value
Reserved code
00 ID 46 27 00 ......Command valid
ID C6 (CRC) C6:Function Code 00: Reserved code
Address of setting module 1~247
Function Code
Read power on value
Reserved code
00 46 28 ......Module command line
DD: Power on value
ID C6 (CRC) C6:Function Code 00: Reserved code