Download Print this page

Trycom Technology TRP-C29U User Manual page 23

8-channel isolated digital input and 8-channel isolated digital output(o.c) usb serial interface module, support ascii and modbus protocol.

Advertisement

*Single-Channel mode( Output control for one BIT)
Example:
Send command:"#011001"..... Data="01":DO0="1".
Response:">"....... Command valid.
Send command:"#011201"..... Data="01":DO2="1".
Response:">"....... Command valid.
Send command:#011700......Data="00":DO7="0".
Response:">"........Command valid.
*1:Digital output enable,0:digital output disable.
8-5. Read digital input N channel counter value
Example:
Send command:"#012".....Read the TRP-C29UM channel 2 counter value.
Response:"!0100023".....The digital input have been trigger 23 times.
*Unless you save value to EEPROM by using the command "#IDCS". The counter's value will
reset to 0 if power fail or send command "$IDRS".
8-6. Clear digital input N channel counter value