Command
#IDCN(CHK)(cr)
#
Syntax
ID
Description
C
N
CHK
(cr)
Response
!ID(CHK)(cr)
?ID(CHK)(cr)
Example:
Send command:"#01C2", Clear CH2 counter value to 0.
Response:"!01".
*If counter's value already been reset to 0 you must use command "#IDCS" to save the new
value in EEPROM again, or the module will load old value if power fail or reset.
8-7.Clear all digital input counters value
Example:
Send command: "#01CW", Clear DI0-DI7 counter value to 0.
Response:"!01".
* After the command "#IDCW" you must save new value in EEPROM again, or the module will
load old value if power fail or reset.
8-8.Save all digital input counters value to EEPROM
First leading code
Address of setting module 00~FF(HEX)
Clear N channel counter value to 0
N=0-7 *Channel DI0~DI7 digital input
Checksum
Carriage return
Parameter invalid
Command Invalid
24