Download Print this page

Trycom Technology TRP-C29U User Manual page 39

8-channel isolated digital input and 8-channel isolated digital output(o.c) usb serial interface module, support ascii and modbus protocol.

Advertisement

Command
ID 46 07 00 (CRC)
ID
Syntax
46
Description
07
00
Response
ID 46 07 YY MM DD 00(CRC)
ID C6 00 (CRC)
Example:
Send Command:"01 46 07 00".......Set up TRP-C29U's configuration.
Response:"01 46 07 09 07 03 00"...JUY. 03.2009 TRP-C29U Firmware Version.
Error Response: "01 C6 00"......Error code.
10-6.Read module reset status
Command
ID 46 08 00(CRC)
ID
Syntax
Description
46
08
00
Response
ID 46 08 0D 00 (CRC)
ID C6 00 (CRC)
Example:
Send Command:"01 46 08 00"...Read the module's digital input status.
Response:"01 46 08 1 00 ..have been reset.
10-7.Reset
Address of setting module 1~247
Function Code
Read module's Firmware
Reserved code
ID 46 07 ......Module command Line
YY:Year MM :Month DD:Date
00 : Reserved code
ID C6 (CRC) C6:Function Code 00: Reserved code
Address of setting module 1~247
Function Code
Read Module Reset status
Reserved code
D=0 Have been read, D=1 Have been reset
ID C6 (CRC) C6:Function Code 00: Reserved code
39