Command
$ID2(CHK)(cr)
$
Syntax
ID
Description
2
CHK
(cr)
Response !IDPPBBDD(CHK)(cr) Command valid
?ID(CHK)(cr)
Example:
Send command:$012...Read configuration .
Response:"! 01400603"....... DIO type=40,Baud-Rate=9600 (See 7.2) ,Data format=03 Input
counter :rising ,Checksum= disable, Model=3....TRP-C29UM.
8-13.Reset
Command
$IDRS(CHK)(cr)
$
Syntax
ID
Description
RS
CHK
(cr)
Response
!ID(CHK)(cr)
?ID(CHK)(cr)
Example:
Send command:"$01RS".......Reset TRP-C29UM.
Response:"!01 "......... ..............Have been reset.
8-14.Read the module's name
First leading code
Address of setting module 00~FF(HEX)
Read configuration
Checksum
Carriage return
PP: Digital I/O type=40
BB: Baud rate
DD=Data format (See data format table)
Module model BIT0~2="000":TRP-C28
" 001" TRP-C24
" 010" TRP-C26
" 011" TRP-C29U
Command Invalid
First leading code
Address of setting module 00~FF(HEX)
Reset the TRP-C29U module
Checksum
Carriage return
Command valid
Command Invalid
27