PG4UWMC
indicate readiness of the program to repeat last operation with new device. After the program
indicates one or more pins of (new) device in the ZIF socket, the LED Busy goes light
continually. From this point the program waits a requested time for insertion of the rest pins of
new device. If a requested time (Device insertion complete time) overflows and a device is not
correctly inserted, the program will light the LED Error to indicate this state. When new device
is inserted correctly, the status LED goes off and a new operation with device is started.
Enable sound when ready for a new device - when checked, sound will be generated if SW
detects complete empty ZIF socket and is ready to accept new device into ZIF socket.
When any of previous options is selected and confirmed by OK button, PG4UWMC send
selected settings to all connected programming site. Also if you set Automatic YES!
parameters on master programming site these settings will be send to all connected slave
programming site sites and to PG4UWMC.
For more details about Automatic YES! feature see Programmer / Automatic YES!.
Other
Colors of the work result LEDs of programmer:
 Standard LED color scheme (ERROR=red, BUSY=yellow)
 Former LED color scheme (ERROR=yellow, BUSY=red)
Note: These settings are available only for some types of programmers. If you can't see
mentioned settings in menu, or menu is not enabled for editing, your programmer doesn't
support LED color scheme customization.
Timer refresh rate defines how often the PG4UWMC program will request status information
from running Programmer Sites. Status information means current device operation type,
progress, result and so on. Current status information is displayed in main window of
PG4UWMC. The default timer refresh rate value is 200ms. If you wish faster refresh of status
information displayed in Operation panel of PG4UWMC, select shorter refresh interval. If you
notice the system performance slow down, when using faster refresh, select higher refresh
value to make refresh less often. On the Pentium 4 computers there is almost no performance
penalty depending on timer refresh rate but on slower computers it is sometimes useful to
select longer (less often) timer interval.
PG4UWMC "Search for Programmers" dialog
Search on local computer
This mode of programmers searching is active after installation of PG4UWMC by default. If
you prefer to operate with programmers connected to different computers via network, try
Network mode.
Red colored programmers (Figure 2) indicate that there are some sites which are expected to
be present, but cannot be found. These sites are listed in "Not found" column. Otherwise the
column is hidden.
133