Technibel SCDF105C5T Technical Data & Service Manual

Technibel SCDF105C5T Technical Data & Service Manual

Freon r410a. cool/dry/fan functions technibel scdf135c5t with remocon control. cool/dry/heat/fan functions with remocon control

Advertisement

Quick Links

TECHNICAL DATA & SERVICE MANUAL
TECHNIBEL SCDF105C5T
TECHNIBEL SCDF135C5T
TECHNIBEL SCDF105R5T
COOL/DRY/FAN FUNCTIONS
WITH REMOCON CONTROL
COOL/DRY/HEAT/FAN FUNCTIONS
WITH REMOCON CONTROL
0.8180.399.1
JULY 2008
FREON R410A

Advertisement

Table of Contents
loading

Summary of Contents for Technibel SCDF105C5T

  • Page 1 TECHNICAL DATA & SERVICE MANUAL FREON R410A TECHNIBEL SCDF105C5T COOL/DRY/FAN FUNCTIONS TECHNIBEL SCDF135C5T WITH REMOCON CONTROL TECHNIBEL SCDF105R5T COOL/DRY/HEAT/FAN FUNCTIONS WITH REMOCON CONTROL 0.8180.399.1 JULY 2008...
  • Page 2: Table Of Contents

    Table of contents Page SPECIFICATIONS 1) Unit specifications 2) Major Component specifications OPERATING RANGE DIMENSIONAL DATA REFRIGERANT FLOW DIAGRAMS PERFORMANCE CHARTS ROOM TEMPERATURE CONTROL HEAT EXCHANGER FROSTING PREVENTION FUNCTIONS 1) Cool Mode Operation 2) Dry Mode Operation 3) Fan Mode Operation 4) Protection operations in Cool and Dry Mode 5) Sleep Function 6) Daily Timer Function...
  • Page 3: Aspecifications

    SPECIFICATIONS 1) UNIT SPECIFICATIONS UNIT MODEL SCDF105C5T SCDF135C5T SCDF105R5T Power source 230 V 50 Hz PERFORMANCES COOLING COOLING HEATING Capacity (air BTU / h 10160 13570 10160 11390 conditioner) 2,98 3,98 2,98 3,34 370/340/270 Air circulation (high/med/low) 370/340/270 450/400/340 Moisture removal (high speed) Cooling l / h 27°C ( 60% R.U.)
  • Page 4: Major Component Specifications

    2) MAJOR COMPONENT SPECIFICATIONS UNIT MODEL SCDF105R5T SCDF105C5T SCDF135C5T CONTROLLER (PCB) Part No. KSA - CTRL - DB Microprocessor Controls Control circuit fuse (F1) 250VAC - 5A -T 2,54mm - 6 pcs Jumper Setting J1….J8 REMOCON RC-7 (ST) REMOTE CONTROL UNIT...
  • Page 5: Boperating Range

    SCDF105R5T SCDF105C5T SCDF135C5T UNIT MODEL CONDENSATE PUMP (PC) Model PC 95643 230 V 50 Hz Rating 12 ± 10% Nominal input 122 ± 10% Coil resistance (at 20° C) Ω SAFETY FLOAT SWITCH (MS) OR (FS) Model F83161,3 10(4)A - 250VAC...
  • Page 6: Cdimensional Data

    DIMENSIONAL DATA SCDF105C5T SCDF135C5T SCDF105R5T REFRIGERANT FLOW DIAGRAM COOLING MODEL REFRIGERANT FLOW DIAGRAM HEAT PUMP MODEL...
  • Page 7: Eperformance Charts

    PERFORMANCE CHARTS OPERATING CHARACTERISTICS WITH RELATIVE HUMIDITY AROUND 50% SCDF105C5T 32 °C 27 °C EXTERNAL TEMPERATURE (°C) 21 °C SCDF135C5T 32 °C 27 °C EXTERNAL TEMPERATURE (°C) 21 °C SCDF105R5T 32 °C 27 °C EXTERNAL TEMPERATURE (°C) 21 °C...
  • Page 8: Froom Temperature Control

    FUNCTION 1) Cool Mode Operation...
  • Page 9: Dry Mode Operation

    2) Dry Mode Operation...
  • Page 10: Fan Mode Operation

    3) Fan Mode Operation 4) Protection operations in Cool and Dry Mode 5 Protection Operations in Cool and Dry Modes...
  • Page 11: Sleep Function

    5) Sleep Function 6) Daily Timer Function 7) IFEEL Function...
  • Page 12: Heat Mode Operation

    TROUBLESHOOTING...
  • Page 13: Auto (Cool/Heat) Mode Operation

    (Operation lamp is blinking) The condensate drain system is obstructed...
  • Page 16 Unit still does Unit still does not run not run...
  • Page 17: Indoor Coil High Pressure Protection In Heat Mode

    Only if IFEEL is selected Temperature difference between suction and discharge Temperature difference between susction and discharge air is large enough (approx. 15°C or more) air too big (approx. 15 °c or more) install an additional unit Only if IFEEL is selected...
  • Page 19: Jtroubleshooting

    CHECKING ELECTRICAL COMPONENTS...
  • Page 21 R.D. 28 Reyrieux BP 131 - 01601 Trévoux CEDEX France Tél. 04.74.00.92.92 - Fax 04.74.00.42.00 R.C.S. Bourg-en-Bresse B 759 200 728...

This manual is also suitable for:

Scdf105r5tScdf135c5t

Table of Contents