Integrated Siren built
The control panel has a high-powered built-in
into the panel
siren that sounds in case of alarm, enabled by
default.
Wired Siren outputs
The control panel can operate a wired siren
and strobe devices
Wired zones and
The control panel can support wired detectors
programmable
and control automation devices with
outputs (PGM)
programmable wired outputs.
Reporting to Private
The PowerMaster system can be
Users and/or
programmed to send notifications of alarm
Monitoring Station by
and other events to 4 private telephone
telephone, SMS and
subscribers by voice and also to 4 SMS
IP communication
cellular phone numbers and to report these
events to the Monitoring Station by SMS,
PSTN or IP communication.
Quick installation with
With PowerG devices, there is no need to
link quality indication
consult the KP-250 PG2 keypad when
mounting a wireless device, because
PowerG devices include a built-in link quality
indicator. Choosing the mounting location is
a quick and easy process.
Device Locator
Helps you to easily identify the actual device
displayed on the KP-250 PG2 LCD display.
Guard key-safe
PowerMaster is able to control a safe that
holds site keys that are accessible only to the
site's guard or Monitoring Station's guard in
the event of an alarm.
Arming key
External system may control arming and
disarming of the PowerMaster system
4
To define whether or not the control
panel's siren will sound upon alarms: see
KP-250 PG2 Installer's Guide, section 3.5.5
Configuring Sirens Functionality
Install and connect wired siren: see
section 3.8 Optional Expander Module
1. Connect a wired zone or PGM device: see
section 3.4 Adding a Wired Zone and Siren.
2. Program the wired zone: see KP-250
PG2 Installer's Guide, section 3.4.2 Adding
New Wireless Devices or Wired Sensors
3. Program PGM outputs behavior: see
KP-250 PG2 Installer's Guide, section 3.7
PGM Output.
To configure notifications to Private
phones: see KP-250 PG2 User's Guide,
Chapter 6, section B.12 Programming
Private Phone and SMS Reporting
To configure reporting to the Montioring
Station: see KP-250 PG2 Installer's Guide,
section 3.6.4 Configuring Events Reporting
to Monitoring Stations
To choose the ideal location to mount a
wireless device, see Chapter 2 Choosing the
Installation Location.
To read more on the Device Locator: see
KP-250 PG2 User's Guide, Chapter 3,
Arming and Disarming the System
To use the device locator when bypassing
a zone or when clearing a bypassed zone:
see KP-250 PG2 User's Guide, Chapter 6,
section B.1 Setting the Zone Bypass Scheme
To use the device locator when conducting
the periodic test: see KP-250 PG2 Installer's
Guide, Chapter 4 Periodic Test by Installer
Code or KP-250 PG2 User's Guide, Chapter 8
Periodic Test by User Code.
1. Connect the safe to the panel: see
section 3.8 Optional Expander Module
Mounting, Figure 3.8b
2. Configure the safe's zone type to
"Guard Zone": see KP-250 PG2 Installer's
Guide, section 3.4.2 Adding New Wireless
Devices or Wired Sensors
3. Setup guard code: see KP-250 PG2
Installer's Guide, section 3.3 Setting Installer
Codes
Connect the external system output to the
panel: see section 3.8 Optional Expander
Module Mounting, Figure 3.8b
D-304267