Pxga Standard Grille Insta Lation Instructions - Friedrich ZoneAire PDE07R3SG Installation And Operation Manual

Packaged terminal air conditioners & heat pumps
Hide thumbs Also See for ZoneAire PDE07R3SG:
Table of Contents

Advertisement

PXGAStandard Grille
Installation Instructions
Remove the center support and weatherboard if still installed in
1.
the sleeve.
Insert six plastic grommets into the grille openings from the outside
2.
of the grille as shown in Figure 13.
Insert two #8 x ⅜" sheet metal screws (provided) in the top two
3.
outside edge plastic grommets, and tighten them half way into
the grommets.
Grasp the grille by the attached plastic handles. Position
4.
it with the conde nsate drain kno ckouts facing down.
From inside the building, maneuver the grille through the wall
sleeve and pull toward you until the screw heads are inserted
into the keyhole slots at the top of the wall sleeve. Tighten the
two screws completely.
Figure 13
Standard Grille
WALL SLEEVE
PXGA
Quantity
Stamped Aluminum Grille
1
6
Plastic Grommets
6
#8 x –" Sheet Metal Screws
Standard Grille
Description
Insert the remaining screws into the remaining holes and tighten
5.
securely.
WEATHERBOARD
CENTER SUPPORT
STANDARD GRILLE
12
WARNING
Falling Object Hazard
Not following Installation Instructions for
mounting your air conditioner can result
in property damage, injury, or death.
WALL
SLEEVE
#8 x 3/8"
SHEET METAL
SCREW
PLASTIC GROMMETS
PLASTIC HANDLES
STANDARD
GRILLE
FRP013

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents