INSTALLATION &
OPERATION GUIDE
920-087-04 (10-06)
PTAC
PACKAGED TERMINAL
AIR CON DI TION ERS
& HEAT PUMPS
Standard Control
Remote Thermostat
Seacoast Protected

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HEAT PUMPS and is the answer not in the manual?

Questions and answers

Summary of Contents for Friedrich HEAT PUMPS

  • Page 1 INSTALLATION & OPERATION GUIDE 920-087-04 (10-06) PTAC PACKAGED TERMINAL AIR CON DI TION ERS & HEAT PUMPS Standard Control Remote Thermostat Seacoast Protected...
  • Page 2: Table Of Contents

    920-087-04 Table of Contents Unit Components ...2 Model Number Code ...3 Installation Recommendations ...4 Friedrich Digital Control Features... 5-6 Drain Kit Installation ...7-8 Wall Sleeve Installation ...9-10 Deep Wall Installation ... 11 Standard Grille Installation... 12 Electrical Rating Tables ... 13 Power Cord Information ...
  • Page 3: Model Number Code

    Thank you for your decision to purchase the newly designed Friedrich Packaged Terminal Air Conditioner (PTAC). We are confi dent that you will fi nd this unit a quiet and effi cient example of Friedrich reliability. This Installation and Operation Manual has been designed to insure maximum satisfaction in the performance of your unit.
  • Page 4: Installation Recommendations

    The above suggestions are for reference only and do not represent all possible installations. Please contact the factory for information regarding affects of other installation arrangements. By following these simple recommendations you can be confi dent that your Friedrich PTAC will provide years of worry free operation. 920-087-04...
  • Page 5: Friedrich Digital Control Features

    Restart 180 to 240 seconds. The new Friedrich PTAC uses a digital thermostat to accurately monitor the outdoor coil conditions to allow the heat pump to run Digital Defrost whenever conditions are correct. Running the PTAC in heat pump mode save energy and reduces operating costs. The digital Thermostat thermostat allows maximization of heat pump run time.
  • Page 6 High effi ciency rotary compressors are used on all Friedrich PTACs to maximize durability and effi ciency. The Friedrich PTAC features a 24V AC terminal for connection to an auxiliary fan that may be used to transfer air to adjoining Auxiliary Fan Ready rooms.
  • Page 7 Installation Instructions PXDR10 Drain Kit NOTE: Determine whether drain will be located within the wall, on the indoor side, or will drain to the exterior of the build ing. Follow appropriate instructions below depending on your particular type of installation. Internal Drain (optional for new construction) NOTE: If installing an internal drain, you MUST install a drain kit on the wall sleeve before the wall sleeve is installed.
  • Page 8: Drain Kit Installation

    External Drain (for new construction or unit re place ment) When using an external drain system, the condensate is removed through either of two drain holes on the back of the wall sleeve. Select the drain hole which best meets your drainage situation and install the drain kit. Seal off the other with a cover plate. Drain Tube Installation Peel the backing tape off the gaskets and apply the sticky side to one cover plate and one mounting plate...
  • Page 9: Wall Sleeve Installation

    Wall Sleeve Installation Instructions (PDXWS) NOTE: Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve, chassis and accessories. If the sleeve projects more than 8" into the room, a sub base or other means of support MUST be used. Please read these instructions com plete ly before attempting in stal la tion.
  • Page 10 Figure 6 Dimensions 13¾ " (35 cm) 3. Drill two 3/16" holes through each side of the sleeve approximately 4" from top and 4" from bottom of sleeve. Screw four #10 x 1" screws (included) or appropriate fasteners for your installation, through the holes in the sides of the wall sleeve.
  • Page 11: Deep Wall Installation

    Section II — Deep Wall Installation (PXWE) If the wall is thicker than allowed in the notes in Figure 6, a sheet met al wall sleeve ex ten sion and fl ashing MUST be used. Installation Instructions for the PXWE – 4" Wall Sleeve Extension The following points MUST be considered when installing a wall sleeve extension:...
  • Page 12: Standard Grille Installation

    Installation Instructions Model PXGA Standard Grille 1. Remove the center support and weatherboard if still in stalled in the sleeve. 2. Insert six plastic grommets into the grille openings from the outside of the grille as shown in Figure 9. 3.
  • Page 13: Electrical Rating Tables

    Failure to do so can result in property damage, personal injury and/or death. B. Power Cord Information (230/208V models only) All Friedrich 230/208V PTAC units are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device meets the UL and NEC requirements for cord connected air conditioners effective August 2004.
  • Page 14: Installation Checklist

    Chassis shipping bracket Shipping pallet IMPORTANT: When installing a Friedrich P-Series PTAC into an existing sleeve, it is important to ensure that the unit is installed completely. Inspection of the air seal between the condenser air baffl es and around the indoor mounting fl ange is recommended.
  • Page 15 If the unit has been placed such that there is no room to insert the thumbscrews from the bottom, request a Side Mounting kit (Part No. PXSM) from Friedrich. Locate the service cord or conduit in the notch at the bottom right of the front cover.
  • Page 16: Digital Control User Input Confi Guration

    This occurs regardless of mode. 4) Emergency Heat Override – Switch 7 In the unlikely event of a compressor failure a heat pump unit may be switched to operate in only the electric heat mode until repairs can be made. Moving Dip Switch 7 to ‘ON’.
  • Page 17: Operation

    Digital Control Operation Temperature Display The Friedrich digital PTAC is shipped from the factory to display the desired room temperature on the LED readout. The unit can be confi gured to display the room temperature by simultaneously pressing the ‘Cool’ and ‘High Fan’ buttons for three seconds the display will show an ‘R’...
  • Page 18: Remote Thermostat And Low Voltage Control Connections

    Remote Thermostat and Low Voltage Control Connections Remote Thermostat All Friedrich PD model PTAC units are factory confi gured to be controlled by either the chassis mounted Smart Center or a 24V single stage remote wall mounted thermostat. The thermostat may be auto or manual changeover as long as the control confi...
  • Page 19: Desk Control Terminals

    Desk Control Terminals The Friedrich PD model PTAC has built-in provisions for connection to an external switch to control power to the unit. The switch can be a central desk control system or even a normally open door switch. For desk control operation connect one side of the switch to the D1 terminal and the other to the D2 terminal (See fi...
  • Page 20: Start-Up Checklist

    Assemble the Warranty Certifi cate, the Operation and Installation Manual, all accessory installation instructions and the name, address and telephone number of the Authorized Friedrich Warranty Service Company in the area for the owner or operator.
  • Page 21: Appendix A: Electrical Wiring For 265 Volt Models

    Appendix A: Electrical Wiring for 265 Volt Models NOTE: It is recommended that the PXSB subbase assembly, the PXCJ conduit kit and the PXDS disconnect switch be installed on all hardwired units. If installing a fl ush-fl oor mounted unit, make provisions for all the line voltage power leads and conduit to be removed for ease of maintenance and service to the chassis.
  • Page 22: Routine Maintenance

    J. Routine Maintenance NOTE: Units are to be inspected and ser viced by qual i fi ed service per son nel only. 1. Clean the unit air intake fi lter at least every 300 to 350 hours of operation. Clean the fi lters with a mild detergent in warm water and allow to dry thoroughly before reinstalling.
  • Page 23: Basic Troubleshooting Techniques

    The number of people in the room, number of electrical devices, solar gains, etc. are all variable items that can affect proper sizing of the unit. Friedrich recommends that you consult with an applications engineer for proper sizing. Is the outdoor temperature 60°F or below? The unit is designed for outdoor temperatures above 60°F.
  • Page 24: Digital Control Diagnostics And Test Mode

    Digital Control Diagnostics and Test Mode Diagnostics The Friedrich Smart Center continuously monitors the PTAC unit operation and will store service codes if certain conditions are witnessed. In some cases the unit may take action and shut the unit off until conditions are corrected.
  • Page 25: Accessories

    DIGITAL REMOTE WALL THERMOSTAT Single stage thermostat features high/low fan speed switch. Thermostat is hard wired and can be battery powered or unit powered. Features backlit display and multiple confi guration modes. For use on PD-series Friedrich PTACs only. REMOTE THERMOSTAT ESCUTCHEON KIT This kit contains...
  • Page 26: Accessories

    SLEEVE EXTENSION RETROFIT KIT Galvanized zinc coated steel, 2.4" sleeve extension attached to the room side of the PXSE sleeve to allow for the installation of a PD-Series Friedrich PTAC in a T-Series sleeve. LATERAL DUCT ADAPTER Attaches to the PTAC/PTHP...
  • Page 27: Warranty

    Unless specified otherwise herein, the following applies: PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS LIMITED WARRANTY - FIRST YEAR (Eighteen (18) Months from the original date of purchase or twelve (12) months from installation).
  • Page 28 Friedrich Air Conditioning Co. Post Office Box 1540 • San Antonio, Texas 78295-1540 4200 N. Pan Am Expressway • San Antonio, Texas 78218-5212 (210) 357-4400 • FAX (210) 357-4480 www.friedrich.com Printed in the U.S.A. 920-087-04 (10-06)