4. Default Settings

Default settings for the I-7060D DIO modules are as follows:
。 Module Address: 01
。 DIO Type: Type 40
。 Baud Rate: 9600 bps
。 Checksum disabled
。 J3 set to INIT mode enabled for I-7043/43D.
5. Configuration
To install the module, follow the steps below:
1. Connect the analog output.
2. Connect the module to the RS-485 network using the DATA+ and DATA- terminals. If
the host is only equipped with an RS-232 interface, then an RS-232 to RS-485
converter will be required.
3. Connect the module to the power supply using the +Vs and GND terminals. Note that
the voltage supplied should be in the range of +10 to +30V DC.