Data composition of output instance 150
Byte
bit
Specifications
0
0
Fault FL
0
1
Fault
0
2
Alarm
0
3
(Reserved)
Motor #1/#2
0
4
(THR2 selection)
0
5
PI control
Acceleration/
Deceleration
0
6
#1/#2 selection
(AD2 selection)
0
7
DC braking
1
0
JOG run
Forward run/
1
1
Reverse run
1
2
Run/Stop
1
3
Coasting (ST off)
1
4
Emergency stop
Ready for operation
1
5
ST=ON
1
6
Ready for operation
1
7 **
Local/Remote
* Ready for operation: Initialization completed, not a stop due to a failure, no alarm issued, not moff, not a forced stop
due to ll, not a forced stop due to a momentary power failure.
** It is reserved in VF-AS1.
0
No output
Output
No trip
Tripped
No alarm
Alarm issued
-
Motor #1
Motor #2
(THR1)
(THR2)
PI control
PI control
permission
prohibition
Acceleration/
Acceleration/
Deceleration #1
Deceleration #2
(AD1)
(AD2)
Forced DC
OFF
braking
OFF
JOG run
Forward run
Reverse run
Stop
Run
ST=ON
ST=OFF
No emergency
Emergency stop
stop
Getting ready for
Ready for
operation
operation
Getting ready for
Ready for
operation
operation *
Remote
Local
- 17 -
1
Supplement
The rtry status and the trip retention
status are also regarded as tripped
statuses.
-
Indicates the motor electronic-thermal
protection level selected.
0: Protection level #1 (thr)
1: Protection level #2 (f173)
Indicates the acceleration/deceleration
time selected.
0: acc, dec
1: f500, f501
ST=ON and RUN=ON in addition to
"ready for operation"*
E6581295⑥
-
-
-
-
-
-
-
-
-
-
-
-