NOTE: 1. Ignition module, valve, pilot, and
IGNITION MODULE 3 VAC
INTERMITTENT PILOT IGNITOR
wall switch operate on 3 volts. 110-120 VAC
is required at junction box unless equipped
I
with battery back-up.
S
TRANSFORMER
WHITE
3 VAC
ORANGE
GROUND TO
FIREPLACE
PLUG IN
CHASSIS
WIRES
BATTERY PACK
(TO BROWN)
WIRE ASSEMBLY
VALVE
Figure 8.2 Intellifire Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Thermostat (Standard)
NOTE: 1. Ignition module, valve, pilot, and
INTERMITTENT
IGNITION
PILOT IGNITOR
MODULE 3 VAC
wall switch operate on 3 volts. 110-120 VAC
is required at junction box unless equipped
I
with battery back-up.
S
TRANSFORMER
ORANGE
3 VAC
WHITE
GROUND TO
FIREPLACE
PLUG IN
CHASSIS
WIRES
BATTERY PACK
(TO BROWN)
REMOTE
PLUG IN
VALVE
Figure 8.3 Intellifire Ignition Wiring Diagram with Optional Remote Receiver Installed