Majestic QUARTZ42 Installation Manual page 20

Table of Contents

Advertisement

Top Vent - Horizontal Termination
One Elbow
Note: Use SLP Series
components only.
WARNING *
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fireplaces, a one foot minimum
vertical vent section is required before installing
first elbow.
**
Note: When using SLP-FLEX (6-5/8 in.) venting, there
MUST be a 25% reduction in total H when using flex vent.
Figure 4.10
20
Majestic • QUARTZ32, QUARTZ36, QUARTZ42 Installation Manual • 2412-980 Rev. Q • 3/19
H
1
*
V
Minimum
1
90 Elbow
1/2 ft.
152 mm
1-1/2 ft.
457 mm
2-1/2 ft.
762 mm
3-1/2 ft.
1.1 m
4-1/2 ft.
1.4 m
H MAX. =14 ft. (4.3 m)
V + H MAX. = 40 ft. (12.2 m)
*
See warning below
V
1
**
H
Maximum
1
18 in.
457 mm
2 ft.
610 mm
3 ft.
914 mm
5 ft.
1.5 m
7 ft.
2.1 m
14 ft.
4.3 m

Advertisement

Table of Contents
loading

Table of Contents