Top Vent - Horizontal Termination - (continued)
Three Elbows
Note: Use SLP Series
components only.
**
Note: When using SLP-FLEX (6-5/8 in.) venting, there
MUST be a 25% reduction in total H when using flex vent.
WARNING *
Fire Risk.
• When using SLP-HRC-SS termination cap
on top vented fireplaces, a one foot minimum
vertical vent section is required before installing
first elbow.
Figure 4.12
22
Majestic • QUARTZ32, QUARTZ36, QUARTZ42 Installation Manual • 2412-980 Rev. Q • 3/19
H
2
V
Minimum
1
90 Elbow
1/2 ft.
152 mm
1-1/2 ft.
457 mm 10 ft.
2-1/2 ft.
762 mm 12 ft.
3-1/2 ft.
1.1 m
*
No specific restrictions on this value EXCEPT V
V
2
H
1
*
**
H
+ H
Maximum
1
2
2 ft.
610 mm
6 ft.
1.8 m
3.0 m
3.7 m
14 ft.
4.3 m
H
+ H
MAX. =14 ft. (4.6 m)
1
2
V
+ V
+ H
+ H
MAX. = 40 ft. (12.2 m)
1
2
1
2
exceed 40 ft. (12.2 m)
*
See warning below
V
1
V
V
+ V
Min.
2
1
2
*
*
*
*
*
*
*
*
*
*
+ V
+ H cannot