Program Lock Mode - LOCK

The LOCK Option allows individual User Programs or a Cone Fire programs to be locked into memory, preventing the settings
from being changed.
LOCK requires a passcode to enable this feature, the default passcode is '3'. Once enabled, the user can set a new passcode
that is private. Lock options will appear at the end of each program sequence. If the passcode is entered during the program
sequence, the program will no longer be available for editing without the passcode.
To turn off the lock feature, the passcode must be re-entered. To reset the passcode, see RST option
Press the Increase/Option key until OPT2 appears, then press Program/Start key, Press Increase/Option until LOCK appears.
Press Program/Start to see PASS. Use the Increase or Decrease key to set the passcode then press Program/Start. use the
Increase or Decrease key to change the setting or to set a new passcode, then press Program/Start.

Auxiliary Output 1 - AOP1

The AOP1 Option sets the Auxiliary relay output to the desired functions for controlling a Vent fan, External alarm or Safety
relay. Setting the AOP1 option to VFAN enables the FN ramp segment for User Programs.
Settings
NONE
VFAN
ALRM
SAFE
Press the Increase/Option key until OPT2 appears, then press Program/Start key, Press Increase/Option until AOP1 appears.
Press Program/Start to see the setting. Use the Increase or Decrease key to edit the setting, then press Program/Start to exit
the option menu.

Electronics Temperature - ELEC

ELEC displays the controller electronics temperature. This can be useful in monitoring the electronics temperature in hot
environments or for diagnosing a controller problem. The ETH alarm will activate if the controller temperature is above 80°C
(176°F)
Press the Increase/Option key until OPT2 appears, then press Program/Start key, Press Increase/Option until ELEC appears.
Press Program/Start to see the result. Press Program/Start to exit the option menu.
Level 3 Options

Cone-fire Cooling Ramp - COOL

The Cooling Option is used for Cone-fire programs only. The controller programming sequence for Cone-fire can include a
cooling step at the end of the firing or this option can be removed from the programming sequence.
Settings
OFF
ON
First, start a CONE program to make the COOL option appear in the option menu. Press the Increase/Option key until OPT3
appears, then press Program/Start key, Press Increase/Option until COOL appears. Press Program/Start to see the setting.
Use the Increase or Decrease key to edit the setting, then press Program/Start to exit the option menu.
AF4X Kiln Controller
Meaning
No external relay functions
Vent fan is enabled on output 2
Alarm is enabled on output 2
Safety Relay is enabled on output 2
Meaning
COOL options inactive and will not appear for Cone-fire
COOL option active and will appear for Cone-fire