Appendix G – Configuration Options
The configuration menu allows you to enable or disable the preset program groups and adjust some of the common
default settings for the controller.
To access the configuration menu. Press and Hold all 3 keys during power on. The display will show RST
Press the Program/Start key, the display will show MODE/1
Press the Program/Start key, the display will show SPD
Press the Increase/Option key to select YES or NO for Speed program group
Press the Program/Start key, the display will show JWL
Press the Increase/Option key to select YES or NO for Jewelry program group
Press the Program/Start key, the display will show CLAY
Press the Increase/Option key to select YES or NO for PMC program group
Press the Program/Start key, the display will show CONE
Press the Increase/Option key to select YES or NO for Cone program group
Press the Program/Start key, the display will show CLAY
Press the Increase/Option key to select YES or NO for PMC program group
Press the Program/Start key, the display will show USER
Press the Increase/Option key to select YES or NO for User Program group
Press the Program/Start key, the display will show TC
Press the Increase/Option key to select a thermocouple type setting
Press the Program/Start key, the display will show F/C
Press the Increase/Option key to select a temperature unit setting
Press the Program/Start key, the display will show PID
Press the Increase/Option key to select a Kiln type BRICK or FIBER
Press the Program/Start key, the display will show SPCL
Press the Increase/Option key to select ON or OFF for rapid heating
OFF – heats as fast as possible to setpoint when rate is FULL
ON – Slows heating to prevent overshoot prior to reaching setpoint when rate is FULL
Press the Program/Start key, the display will show SFTY
Press the Increase/Option key to set the max firing temperature
Press the Program/Start key, the display will show USR
Press the Increase/Option key to select the number of user programs
Press the Program/Start key, the display will show AOP1
Press the Increase/Option key to select function for the secondary relay output
Press the Program/Start key, the display will show DELA
Press the Increase/Option key to select a Delay start mode
Press the Program/Start key, the display will show IDLE
From IDLE, you can program up to 10 custom user programs that will be preset and unavailable for editing. You
must enter the complete programs into PR01-PR10 before powering off the controller.
Power off and restart the controller.