AutoFire® Kiln Controller
Cone Fire -
using your controller for preset cone programs.
The Up Arrow
The Right Arrow
The AutoFire® family of kiln controllers feature easy firing to any cone number.
Just follow these simple steps:
Step
Press
1
CONE FIRE
2
UP ARROW/
RIGHT ARROW
3
ENTER
4
UP ARROW/
RIGHT ARROW
5
ENTER
(At this point additional options can be selected, such as delay start, firing speed, or cone offset)
6
STOP/START
7
-
8
STOP/START
For more information on additional features and options, refer to the appropriate sections in this User's Guide.
increments the value 0 – 9, or scrolls through selections one at a time.
shifts editing digit to the right, or scrolls through selections one at a time.
(Controller temperature is displayed in °F)
Description
Enters the Cone Fire mode. The "06" is the cone
program name and the "1828" is the corresponding
cone deformation temperature at a 108°F/hr ramp.
Scroll to the desired cone number. The desired
preset cone program name and the corresponding
cone deformation temperature at the 108°F/hr ramp
will be alternatively displayed.
Selects the desired cone number currently displayed.
Then advances to Hold Time (Hd). Use arrows to
select up to 30 minutes of hold time at the end
of Cone Fire program. If no hold time is desired then
simply press [ENTER]. The controller returns to Idle mode.
Scroll to the desired hold time. The default is 0 hold.
(Hold times are in 5 minute increments)
Selects the displayed hold time.
Starts the selected cone firing. The current kiln
temperature is displayed during an active firing cycle.
When the active firing cycle is completed. The final
temperature reached by the kiln will be alternately
shown as CPLt in the display.
Acknowledges completion of the firing cycle
and returns to IdLE mode. Also functions
as Abort (Abrt) during a firing process.
User's Guide
Display
06, 1828
022, 1086 to
12, 2382
Hd, . 0
0, 5, 10, 15, 20, 25, 30
IdLE
XXXX, where XXXX
is current temperature
CPLt, Final
Temperature
IdLE
Abrt
7