Power Interruption Alarms; Diagnostic Alarms; Options Menu - Orton MILL IRON TOOLS Arrow Springs AutoFire ASC/6 User Manual

Table of Contents

Advertisement

Power Interruption Alarms

Power failed and firing was resumed
PF
Power failed during cooling and firing was stopped because cooling temperature exceeded
PF 1
Power failed during heating and firing was stopped because temperature was below 212°F
PF 2
Power failed during heating or hold and firing was stopped because temperature dropped by 72°F
PF 3

Diagnostic Alarms

Invalid User Program. Check current kiln temperature is below program temperature.
BADP
Electronics too Hot – controller temperature above 80°C, firing stopped
ETH
Failed to read or write to memory device
FE 1
Errors detecting thermocouple input signal
FE 4

Options Menu

Advanced settings and features are available through the Options menu. Press the Increase/Option
Key to advance through the options menu. During a firing, not all options can be changed. To exit
Options, select the EXIT prompt within the option menu.
To view an Option setting, press Program/Start key when the option code is displayed. Use the Increase or
Decrease key to change the setting for the option. Press Program/Start after making the change.
Option List
SKIP
Skip Step
HLDT
Hold Time
CHGT
Change Temperature
DELA
Delay
TC
Thermocouple Type
ALAR
Threshold Alarm
DIAG/TEST
Diagnostics
F/C
Temperature Units
LIM
Over-Temperature Limit
COST
Firing Cost
EXIT
Exit option menu
OPT2
Level 2 Options
OFST
Cone Offset
TCOS
Thermocouple Offset
TEDE
Temperature Deviation
HTDE
High Temperature Deviation
LOCK
Program Lock
AOP1
Auxiliary Output #1
ELEC
Electronics Temperature
EXIT
Exit option menu
OPT3
Level 3 Options
COOL
Cone-Fire Cooling
RATE
Ramp Rate units
CENT
Cost per Kilowatt Hour
KW
Kiln Power Rating
SFTY
Safety Temperature
SOFT
Software Version
CFG
Configuration Number
RST
Factory Reset
AF4X Kiln Controller
Skip ahead in the running program
Add Time to the current hold segment
Change the current target temperature
Change Delay start mode
Select thermocouple type (Type K, N, S or R
Set Alarm temperature
View output amps or test outputs.
Change temperature units to °F or °C
Set the maximum limit temperature
View calculated firing cost
Adjust firing temperature to match witness cones by
Change a thermocouple temperature reading by
Deviation value for alarms FTH, FTC, and LTDE
Deviation value for alarm HTDE
Lock or Unlock the programs to prevent changes
Enable a vent fan, external alarm or safety relay output on Output 1
Displays temperature of the electronics
Enable or disable cooling option for Cone-fire
Select ramp rate units of degrees per hour, minute or Time
Set firing cost for Kilowatt Hours
Set power consumption Kilowatts
Displays maximum programmable temperature
Displays factory software version
Displays factory configuration #
Reset all values to OEM settings.