Reset - RST
The RST feature restores the original OEM values supplied with the controller. Do not perform a reset unless all other efforts to
correct faults with the controller have failed. A reset may change important option settings for your kiln. Before attempting a
reset, you should become familiar with the correct option settings for your controller. Most important is the TC option setting.
To reset, Press the Increase/Option key until OPT3 appears, then press Program/Start key. Press Increase/Option until RST
appears. Use the Increase or Decrease key to edit the setting from NO to YES and press Program/Start. This will reset the
controller settings. Verify the controller is accurately displaying temperature after the reset. You may need to adjust the TC
setting for the thermocouple and the F/C setting for the display temperature.
Hardware Options
Audible alarm buzzer
The audible alarm can be disabled by removing the circuit board jumper on the back side of the controller. remove
the jumper shunt labeled BUZZ ENABLE along the top edge of the circuit board.
Door/Lid switch
An optional door switch can be installed and connected to the controller. If not used, a jumper shunt is placed at
circuit board location labeled LID.
LID is also a display alarm that indicates when the switch connection is open.
The door switch acts an optional safety device to prevent the relay outputs from being energized whenever the kiln
door or lid is open.
Computer software
Computer software is available for remote monitoring and datalogging. The controller has a USB interface that
outputs TIME, Temperature and Setpoint data. For more information on the optional computer software, contact
Orton or visit
www.ortonceramic.com
Speed Programs
5 speed programs are preset firing schedules with different fixed heating rates. These programs are single set-point
(one step) programs.
The 5 programs are;
Display code
SPD1
SPD2
SPD3
SPD4
SPD5
* The operator can adjust the final firing temperature and optional hold time
For information on rates, target temperatures and hold times, see the user program section of this manual.
AF4X Kiln Controller
Program
Rate
Speed 1
200F(111C)/hour
Speed 2
500F(278C)/hour
Speed 3
1000F(555C)/hour
Speed 4
1500F(833C)/hour
Speed 5
Full
19
Target
Hold
1112F(600C) *
00.00 *
1112F(600C) *
00.00 *
1112F(600C) *
00.00 *
1112F(600C) *
00.00 *
1112F(600C) *
00.00 *