Technical Data - EUCHNER MGB-L0 AR Series Operating Instructions Manual

Safety systems
Hide thumbs Also See for MGB-L0 AR Series:
Table of Contents

Advertisement

Operating Instructions Safety Systems
MGB-L0...-AR.-... and MGB-L0...-AP.-...

13. Technical data

NOTICE
If a product data sheet is included with the product, the information on the data sheet applies in case
of discrepancies with the operating instructions.
Parameter
Housing material
Dimensions
Weight
Interlocking module
Handle module
Escape release
Ambient temperature at U
= DC 24 V
B
Degree of protection
Cover not populated/populated with buttons/indi-
cators/selector switches
Cover populated with key-operated switch
Cover populated with key-operated rotary switch FS22
Safety class
Degree of contamination
Installation position
Connection
Conductor cross-section (rigid/flexible)
- With ferrule according to DIN 46228/1
- With ferrule with collar according to DIN 46228/1
Operating voltage UB
(reverse polarity protected, regulated, residual
ripple < 5 %)
Auxiliary voltage UA
(reverse polarity protected, regulated, residual
ripple < 5 %)
Current consumption I
(no load on any outputs)
UB
Current consumption I
UA
- Pushbutton S (unloaded, per LED)
External fuse
Safety outputs FO1A/FO1B
Test pulses
Test-pulse interval
Output voltage U
/ U
1)
FO1A
FO1B
HIGH
U
/ U
FO1A
LOW
U
/ U
FO1A
Switching current per safety output
Utilization category according to EN IEC 60947-5-2
Monitoring outputs
- Output voltage
1)
- Max. load
Rated insulation voltage U
i
Rated impulse withstand voltage U
Resilience to vibration
Switching frequency
EMC protection requirements
Reliability values acc. to EN ISO 13849-1
Category
Performance Level
PFH
D
Mission time
Mechanical life
- In case of use as door stop, and 1 Joule impact
energy
B
(emergency stop)
10D
Emergency stop
Operating voltage
Operating current
Breaking capacity max.
Power supply LED
Controls and indicators
Operating voltage
Operating current
Breaking capacity max.
Power supply LED
1)
Values at a switching current of 50 mA without taking into account the cable length.
2)
Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), the employers' liability insurance association certifies a PFHd of max. 2.47 x 10
32
FO1B
FO1B
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.
imp
Value
Fiber glass reinforced plastic
die-cast zinc, nickel-plated
stainless steel
See chapter 7.4. Dimension drawing on page 12
0.75
1.00
0.50
-20 ... +55
IP 65
IP 54
IP 42
III
3
Any
4 cable entries M20x1.5 or plug connector
0.13 ... 1.5 (AWG 24 ... AWG 16)
0.25 ... 1.5
0.25 ... 0.75
24 +10% / -15% (PELV)
24 +10% / -15% (PELV)
80
5
See chapter 11.3. Fuse protection for power supply on page 22
Semiconductor outputs, p-switching, short circuit-proof
AR < 1,000/AP < 300
Min. 100
U
-2V ... U
B
0 ... 1
1 ... 200
DC-13 24 V 200 mA
p-switching, short circuit-proof
U
- 2V ... U
A
Max. 50
30
1.5
Acc. to EN IEC 60947-5-3
0.25
Acc. to EN IEC 60947-5-3
4
PL e
3.7 x 10
/ h
-9
20
1 x 10
6
0.1 x 10
0.065 x 10
5 ... 24
1 ... 100
250
24
UA
1 ... 10
250
24
(translation of the original operating instructions) 2112657-13-05/18
B
A
2)
6
6
Unit
kg
°C
mm²
V DC
V DC
mA
mA
µs
ms
V DC
mA
mA
V
kV
Hz
years
V
mA
mW
V DC
V
mA
mW
V DC
.
-8

Advertisement

Table of Contents