Forced operation

• If the product is not used for a long time, the product will be forced to operate to prevent pump
failure and PHEX freezing
• Water pump off After 20 consecutive hours, disable / enable the logic that drives the water
pump by itself
• In the installer setting list, select Forced operation category, and press [OK] button to move to
the detail screen
Type
Oper. Cycle
Oper. Time
OK
Use
20 minutes ~ 60 minutes
1 Minute ~ 60 minutes
INSTALLER SETTING
Not use
-
-