GENERAL INFORMATION
30
Description
Category
Symbol
S9
Refrigerant temperature sensor (Gas side)
S10
Refrigerant temperature sensor (Liquid side)
S11
Water temperature sensor (Water In)
S12
Water temperature sensor (Water Out)
F/S
Flow Switch
E/HT
Electric Heater
Unit
W_PUMP1
Internal Water Pump
EXP/TANK
Expansion Tank
S14
Remote Air temperature sensor
CTR/PNL
Remote Controller
2WAY V/V_1 To control water flow for Fan Coil Unit
M / F
Magnetic Filter
W/TANK
DHW Tank
B/HT
Booster heater(in DHW tank)
Water
- Flow control for water which is leaving from unit.
Heating
3WAY V/V_1
- Flow direction switching between underfloor and
water tank
Water to be heated by Indoor unit and B/HT of
CITY WATER
W/TANK
SHOWER
Water supplied to end-user
S15
W/TANK water temperature sensor
S16
Solar-heated water temperature sensor
- Flow control for water which is heated and
circulated by SOLAR THERMAL SYSTEM.
3WAY V/V_2
- Flow direction switching between SOLAR
THERMAL SYSTEM and W/TANK
Solar
Heating
W_PUMP/2
External Water Pump
- This system can include following components :
SOLAR
Solar panel, Sensors, Thermostats, Interim heat
THERMAL
exchanger, Water pump, etc.
- To utilized hot water heated by SOLAR THERMAL
SYSTEM
SYSTEM, end-user must by LG AWHP Solar-Kit.
Meaning
PCB Connector
CN_PIPE_OUT
CN_PIPE_IN
Water _OUT
CN_FLOW1
CN_E/HEAT(A)
CN_E/HEAT(B)
CN_MOTOR1
(no connector)
CN_ROOM
CN_REMO
CN_2WAY(A)
(No connector)
(no connector)
CN_B/HEAT(A)
CN_3WAY(A)
(no connector)
(no connector)
CN_3WAY(B)
CN_W/PUMP(B)
(no connector)
- Meaning is expressed based on Cooling mode.
Water _IN
- Optional accessory (sold separately)
- Model : HA**1A E1
- Heating capacity is divided into two level : partial
capacity by E/HEAT(A) and full capacity by
E/HEAT(A) + E/HEAT(B).
- Operating power(220-240 V~ 50 Hz) of E/HEAT(A)
and E/HEAT(B) are supplied by external power
source via relay connector and ELB.
- Water Pump is connected at CN_MOTOR1
- Absorb volume change of heated water,
- Optional accessory (sold separately)
- Model : PQRSTA0
rd
- 3
party accessory and Field installation (sold
separately)
- 2 wire NO or NC type 2way valve is supported.
rd
- 3
party accessory and Field installation (sold
separately)
- It is Mandatory to install an additional filter on the
heating water circuit.
- 3rd party accessory and Field installation (sold
separately)
- Generating and storing DHW by AWHP or built-in
electric heater
rd
- 3
party accessory and Field installation (usually
built-in at W/TANK)
- Supplying additional water heating capacity.
rd
- 3
party accessory and Field installation (sold
separately)
- SPDT type 3way valve is supported.
- Field installation
- Field installation
- S15 and S16 are connected at 4 pin type connector
CN_TH4.
CN_TH4
- S15 is a part of DHW tank kit.(Model : PHLTB)
- S16 is a part of solar thermal kit (Model:PHLLA)
rd
- 3
party accessory and Field installation (sold
separately)
- SPDT type 3way valve is supported.
rd
- 3
party accessory and Field installation (sold
separately)
- If water pump of SOLAR THERMAL SYSTEM is
incapable of circulation,external water pump can be
used.
rd
- 3
party accessory and Field installation (sold
separately)
Remarks