Pump setting. in cooling

• It is a function to help the water pump's mechanical life by putting the water pump's rest time
• installer setting function to set water pump operation / delay time option in cooling mode
• In the installer setting list, select Pump setting in cooling category, and press [OK] button to
move to the detail screen.
Type
Time setting
On
1 Minute ~ 60 minutes
Off
1 Minute ~ 60 minutes
OK
Operation continue
-
-