Advertisement

Window Type Air Conditioner
KAG-80HME4
KAG-100HME4
KAG-150HME4
KAG-200HME4
KAG-250HME4
Thank you for choosing our product.
For proper operation, please read and keep this manual carefully.
If you have lost the Owner's Manual, please contact the local agent or visit www.kolinphil.com.ph.
KAG-80HRE4
KAG-100HRE4
KAG-150HRE4
KAG-200HRE4
KAG-250HRE4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the e Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Kolin e Series

  • Page 1 Window Type Air Conditioner KAG-80HME4 KAG-80HRE4 KAG-100HME4 KAG-100HRE4 KAG-150HME4 KAG-150HRE4 KAG-200HME4 KAG-200HRE4 KAG-250HME4 KAG-250HRE4 Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner’s Manual, please contact the local agent or visit www.kolinphil.com.ph.
  • Page 2: Table Of Contents

    CONTENTS Thank you for choosing Kolin air conditioner. Our design is based on the best efficiency and the lowest noise operation and it can keep the room comfortable. Please read this operating manual carefully before operating the unit and keep it for consultation.
  • Page 3: Precautions

    Precautions Warning This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Page 4: Function

    Function Introduction Autumn Spring Window type room air conditioners of Kolin can regulate the room Summer Winter Room temperature and dry the room. It is convenient for your work,study temp. and life. It can be widely used in residence, shop, hotel, office, library and laboratory, and so on.
  • Page 5: Operating Condition

    Operating Condition Please operate air conditioner in the correct conditions as following. DRY mode operation COOL mode operation to 43 , Outdoor temperature should be in range of 18 Outdoor temperature should be in range of 18 to 43 , otherwise it is possible for air conditioner otherwise it is possible for air conditioner to breakdown.
  • Page 6: Installation

    Installation Installation precaution: Window type conditioner is so valuable and the improper installa- tion of it will cause a lot of damage! Please associate the profes- sional technician to install the unit and don’t install it by yourself. Otherwise, we are not responsible for the damage like this. Location: The condensation water must be drained away conveniently.
  • Page 7 Installation procedure: Horizontal line 1) Remove the sticker from the front panel. 2) Put the unit into the installation hole. 6~10mm When installing the unit, it should be slanted down to the back to avoid the enlargement of noise or vibration. (Slant between 6-10mm.) (Shown at right figure.) The installation place should be strong enough to avoid the enlargement of noise or vibration.
  • Page 8: Notes For Installation

    Note: Drain pan and drain hose must be installed before using reverse cycle models. Drain hose or tubing can be purchased locally to satisfy your particular needs. Notes for installation Remove Before removing air conditioner to the other place, you should contact the seller firstly.
  • Page 9: Part Identification

    Part identIfIcation Note:Panel outlook picture, just for reference, please take the real unit as standard. Cabinet Air inlet louver Front grille Front intake grille) Control panel cover Air filter Power cord (behind the front intake grille) Cabinet Air inlet louver Front grille Front intake grille) Remote control panel...
  • Page 10: Main Switch Operation Procedure

    Main switch operation procedure 1.Only Cooling 1.Main Control Knob Set to Low Cool,Med Cool or High Cool as desired(FAN setting operates the fan only.) CAUTION:If the main control knob is turned off of changed to a fan setting from a cooling operation setting. WAIT at teast 3minutes before resetting to cooling operation.
  • Page 11: Remote Control Operation Procedure

    Remote control operation procedure Buttons on remote controller ON/OFF button MODE button +/- button FAN button SWING button SLEEP button TIMER button Introduction for icons on display screen Timer on Timer off Sending signal auto operation swing operation cool operation sleep operation dry operation lock...
  • Page 12 Introduction for buttons on remote controller Note: ● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 13 Introduction for buttons on remote controller FAN button Pressing this button can select fan speed circularly as: AUTO, SPEED 1 ( SPEED 2 ( SPEED 3 ( ), SPEED 4 ( ) (unavailable in this air conditioner. Speed 4 is the same with speed 3.). AUTO SPEED 1 (equals to low fan speed) SPEED 2 (equals to low fan speed)
  • Page 14 Introduction for buttons on remote controller Note: ● Range of time setting is: 0.5~24h ● The interval between two motions can't exceed 5s, otherwise the remote con- troller will exit setting status. Function introduction for combination buttons Child lock function Press “+”...
  • Page 15 Replacement of batteries in remote controller 1. Press the mark “ ” on back cover of batteries box cover for remote controller with fingers as shown in the fig, and then remove the batteries box cover along the arrow direction. Battery 2.
  • Page 16 Remote control panel Note: If wireless remote controller is lost, open the surface panel and operate manually. POWER BUTTON SIGNAL RECEIVER Operation starts when pressing this button, and stops when pressing this button again. MODE BUTTON SWING BUTTON Select the operation mode, AUTO, HEAT, COOL, Activate the automatic air swing function.
  • Page 17: Operation Tips

    Operation Tips Operation for comfort and economy Do not overcool the room Keep blind or curtains closed . Keep the room temp. uniform. temperature. This is not good Do not let sunshine enter the Adjust the vertical and horizon- for health and wastes electricity. room directly when the air con- tal airflow direction to ensure a dition is in operation.
  • Page 18: Caution

    Caution Operations for safety and health 1) The plug must be accessible after the appliance is positioned. 2) Do not use this appliance in the laundry. 3) If the power cord is damaged, it must be replaced by the manufacture or its service agent in void of hazard. Do not pull out the power cord.
  • Page 19: Care And Maintenance

    Care and maintenance Always turn off the air conditioner and main power supply before cleaning to ensure safety. Cleaning unit 1. Cut power off before cleaning. Air filter The air filter behind the intake grille should be washed at least Plug out only after once every two weeks or as often as it needs cleaning.
  • Page 20: Trouble Shooting Guide

    Trouble shooting guide Please check the following items before asking for repair,it saves your time and money. Fault phenomenon Trouble-shooting * Is there a power failure? * Is the plug out? Air conditioner dose not s power fuse or switch off ? operate at all.
  • Page 21: After Service

    The external static pressure at testing place of AC is 0MPa. After service If your air conditioner has the questions of quality or anything else, please contact the service center of Kolin Philippines International Inc.
  • Page 22 KPII 20190522...

Table of Contents