  • Page 1 VCC-F22V39APCL Rev.900-673-31-00 English VGA Color Camera 49MHz Pixel Clock PoCL/PoCL-Lite VCC-F22V39APCL Product Specification & Operational Manual CIS Corporation ©2009 CIS Corporation. All rights reserved.
  • Page 2: Table Of Contents

    9. Initial Settings ............................. 15 10. CCD Optical Axis Accuracy ........................16 11. Dimensions ............................17 12. Cases for Indemnity (Limited Warranty) ....................18 13. CCD Pixel Defect ..........................19 14. Product Support ..........................19 ©2009 CIS Corporation. All rights reserved.
  • Page 3: Scope Of Application

    The voltage ripple of camera power DC +12V±10% shall be within ±50mV. Improper power supply voltage may cause noises on the video signals. Please avoid noises like chattering when rising power. In case of abnormal operation, contact the distributor from whom you purchased the product. ©2009 CIS Corporation. All rights reserved.
  • Page 4: Product Outline

    Full frame scan mode and three different partial scan modes are available. □ Approx. 120 fps at full frame scan mode. □ Only 29mm cubic in size (excluding projection), light weight 50g, and speed makes it a best match for □ use in embedded systems. ©2009 CIS Corporation. All rights reserved.
  • Page 5: Specification

    OFF (1/120), 1/200, 1/240, 1/500, 1/1000, 1/2000, 1/4000, 1/8000, 1/14000, variable range 1/24000, 1/40000, 1/100000s ・Fixed Trigger Shutter Mode ・Pulse Width Trigger Shutter Mode Trigger shutter mode *Trigger pulse width shall be over 1H and less than 1/2s. ©2009 CIS Corporation. All rights reserved.
  • Page 6 Y, and ±Z, 6 directions. (without package) Temperature Operation guaranteed: -5℃~+45℃ Performance guaranteed: 0℃~+40℃ Operation environment RH 20~80% with no condensation Humidity Temperature -25℃ ~ +60℃ Storage environment RH 20~80% with no condensation Humidity ©2009 CIS Corporation. All rights reserved.
  • Page 7: Camera Output Signal Specification

    R G R G R G R G G B G B G B G B R G R G R G R G 5 seconds shall be waited after turning on power to get proper camera operation. ©2009 CIS Corporation. All rights reserved.
  • Page 8: Ccd Spectral Response (Representative Value)

    VCC-F22V39APCL Rev.900-673-31-00 4.3. CCD Spectral Response (Representative value) ※ Lens characteristics and illuminant characteristics are not considered. ©2009 CIS Corporation. All rights reserved.
  • Page 9: Function Settings

    Partial Scan Mode 1 Scan Mode Partial Scan Mode 2 Partial Scan Mode 3 Manual White Balance 0~255 Covers variable range 2600~9000K. R Gain Control Manual White Balance 0~255 Covers variable range 2600~9000K. B Gain Control ©2009 CIS Corporation. All rights reserved.
  • Page 10 Re-triggering at H-Synchronous Mode shall be after 2H of CCD read out signal. Re-triggering at CLK-Synchronous Mode shall be after completion of video output. Trigger pulse width shall be within the range of over 1HD to less than 1/2 sec. ©2009 CIS Corporation. All rights reserved.
  • Page 11: External Connector Pin Assignment

    6. External Connector Pin Assignment 26pins camera Link connector 12226-1100-00 PL (SUMITOMO 3M) Pin No. Pin No. DC+12V Xclk- Xclk+ SerTC+ SerTC- SerTFG- SerTFG+ CC1- CC1+ (Trigger IN-) (Trigger IN+) CC2+ CC2- CC3- CC3+ CC4+ CC4- (GND) DC+12V ©2009 CIS Corporation. All rights reserved.
  • Page 12: Timing Chart

    525 H Partial Scan Mode 1 18 H 310 H 345 H Partial Scan Mode 2 23 H 222 H 262 H Partial Scan Mode 3 28 H 124 H 13 H 174 H ©2009 CIS Corporation. All rights reserved.
  • Page 13: Trigger Shutter Mode

    Partial Scan Mode 3 28 H 124 H 174 H CLK- Synchronous Mode Details at Pulse Width Trigger Shutter Mode Trigger Input Signals Discharge Signals Read OUT Signals Delay Time 2.3µs Delay Time 12.0µs Exposure Time ©2009 CIS Corporation. All rights reserved.
  • Page 14: Remote Interface Function

    (Reboot the camera, and the data is reset to the initial setting.) To save the data into EEPROM, please refer to Clause 5.4. Function Setting. Note: Once the data was saved into EEPROM, it may not be reset to t he initial settings. ©2009 CIS Corporation. All rights reserved.
  • Page 15: Initial Settings

    Manual White Balance B Gain Control Not specified Manual Gain Control Not specified Manual Shutter Control 009&010 Not specified Trigger Polarity 0: Positive Input Output Data Select 0:RAW 8bit Output Data Trigger Reset Mode 0: H-Synchronous Mode ©2009 CIS Corporation. All rights reserved.
  • Page 16: Ccd Optical Axis Accuracy

    ?? ±0.5° The center of effective pixels shall be Within f 0.6 to the center of lens mount. (*) Dimensions from datum plane to the center of lens mount. 910-007-01-01 (Unit :mm) ©2009 CIS Corporation. All rights reserved.
  • Page 17: Dimensions

    (M2 Size) *) C Mount screws comply with ANSI/ASME B1.1, 1-32UN(2B). *) Screw length from C mount lens surface shall be under 6mm. And protruding portion shall be less than 10mm. 999-512-00-00 (Unit: mm) ©2009 CIS Corporation. All rights reserved.
  • Page 18: Cases For Indemnity (Limited Warranty)

    In case damage or losses are caused by repair or modification conducted by the customer or any unauthorized third party (such as an unauthorized service representative). Expenses we bear on this product shall be limited to the individual price of the product. ©2009 CIS Corporation. All rights reserved.
  • Page 19: Ccd Pixel Defect

    We shall be exempted from taking responsibility and held harmless for damage or malfunction of your hardware and software caused by using this control software. The purpose of this control software is for you to check operation and evaluate our products. Please be noted that CIS does not customize the program nor provide source code.