5 - Operation

Operating Limits

The following things are important when considering the performance of the sprayer.
• Maximum driving speed
• Pressure setting
• Minimum / maximum volume rate
The operating limits for your sprayer are closely related to:
9. Pump size
10. Boom width
11. Nozzle size
In the table below, the operating limits for volume rate are calculated, when driving at different speeds.
Nozzle size
HARDI ISO F-110
4 km/h
02 (yellow)
171
025 (purple)
213
03 (blue)
255
04 (red)
339
05 (brown)
423
06 (grey)
510
08 (white)
678
10 (light blue)
849
÷
NOTE! The specified nozzle type is a standard flat fan nozzle. Other special nozzle types will show different results. Ask
your HARDI dealer if in doubt.
μ
ATTENTION! It is recommended not to drive faster than 16 km/h when spraying.
μ
ATTENTION! The pressure range for the nozzles are 1.5 - 5 bar (except for HARDI INJET nozzles, which are ranging from
3-8 bar). The spraying pressure should be within these limits.
μ
ATTENTION! In the table below, the specified combination of nozzle size and sprayer setup is not suitable, as the full
pressure range of 5 bar for the nozzle cannot be reached, when spraying the maximum volume rate (l/ha) on the crop.
This is due to the nozzle design.
Pump model
364
364
÷
According to the standard for environmental requirements for sprayers, ISO 16119 / EC Directive 2009/127/EC
(amending 2006/42/EC), the farmer shall be able to use the full pressure range.
90
Min. volume rate (l/ha)
8 km/h
12 km/h
85
57
106
71
127
85
170
113
212
141
255
170
339
226
424
283
Boom width
Nozzle size
16 m
10 (light blue)
18 m
10 (light blue)
16 km/h
4 km/h
43
309
53
387
64
465
85
621
106
774
128
930
170
1239
212
1548
Max. volume rate (l/ha)
8 km/h
12 km/h
155
103
194
129
232
155
310
207
387
258
465
310
620
413
774
516
16 km/h
77
97
116
155
194
233
310
387

Advertisement