SIA False Alarm Reduction Installations: Quick Reference

Minimum required system consists of one Control unit model HS2128 or HS2064 or HS2032 or HS2016 and any one of the compatible listed keypads: HS2LCDRF9, HS2LCDRFP9, HS2ICNRF9, HS2ICNRFP9, HS2LCD, HS2LCDP, HS2ICN,
HS2ICNP, HS2LED.
The following wireless keys can also be used in SIA compatible installations: PG9929, PG9939,PG9949.
NOTE: For models PG9929 and PG9939, the panic/emergency key shall be disabled for SIA compliant installations.
For a list of the default values programmed when the unit is shipped from the factory, and for any other programming information, refer to the table below.
The following optional subassembly modules also bear the SIA CP-01-2010 classification and may be used if desired: HSM2108 zone expander, HSM2208 PGM output module, HSM2300 auxiliary power supply, HSM2204 output module,
HSM2HOST9 2-way wireless transceiver, PG9901 indoor siren, PG9911 outdoor siren, and 3G2080(R)/ TL2803G(R)/ TL280(R) cellular and PSDN communication module.
Caution
For SIA FAR installations use only modules/devices that are listed on this page.
Fire Alarm Verification feature (Auto Verified Fire Zone type [025]) is not supported on 2-wire smoke detectors zones, model FSA-210B(T)(S)(ST)(LST)(R)(RT)(RD)(RST)(LRST). This feature may be enabled for 4-wire
smoke detectors only (FSA-410B(T)(S)(ST)(LST)(R)(RT)(RST)(LRST) and wireless detectors PG9916/PG9926). The fire alarm delay is 60s.
Call Waiting Cancel (Section [382], Option 4) feature on a non-Call Waiting line will prevent successful communication to the supervising station.
All smoke detectors on the system must be tested annually by conducting the Installer Walk Test. Prior to exiting walk test mode, a sensor reset must be done on the system, [*][7][2], to reset all latching 4-wire smoke
detectors. Refer to the installation instructions supplied with the detector for details.
Notes
Programming at installation may be subordinate to other UL requirements for the intended application.
Cross zones have the ability to individually protect the intended area (e.g. motion detectors which overlap).
Cross zoning is not recommended for line security Installations nor is it to be implemented on exit/entry zones.
This control panel has a communication delay of 30 seconds. It can be removed or increased up to 45 seconds by the end user in consultation with the installer.
The security system shall be installed with the sounding device activated and the communicator enabled for transmission using SIA or CID format.
ULC commercial burglary installations require DEOL resistors.
SIA Feature Programming Section
Exit Time
[005]>[001], option 3
Progress Annunciation/Disable - for Silent
Exit
[014], option 6 ON
Exit Delay Restart
[018], option 7
Auto Stay Arm on Un-vacated Premises
[001]>[001]-[128] Zone type 05, 06,09
Exit Time and Progress Annunciation/Disable
or Remote Arming
[861]>[001]-[005], option 4
Entry delay(s)
[005]>[001]-[008], options 1 and 2
Abort Window for Non-Fire zones
[002]>[001]-[128], option 7 ON
Abort Window Time - for Non-Fire zones
[377]>[002], option 1
Abort Annunciation
Duress Feature
[*][5]> master code> user 2-95> 5> 2
Cancel Window
[377]>[002], option 6
Cancel Annunciation
[308]>[001], option 8
Cross Zoning
[042]>Selection 3, option 002
Burglary Verification Timer
[005]>[000], option 3
Swinger Shutdown for Alarms
[377]>[001], option 1
Swinger Shutdown Enable
[002]>[001] - [128], option 6 ON
24-Hr. Auto-verified Fire
[001]>[001]-[128], Zone type 025 ON
Call Waiting Cancel
[382], option 4 OFF
System Test:
[*][6] Master Code, option 4
Walk Test Mode:
[*][8][Installer code][901]
Walk Test Communications
[382], option 2
Walk Test Start/ End Reporting Codes
[308][401], options 1 and 2
© 2014 Tyco International Ltd. and its Respective Companies. All Rights Reserved.
The trademarks, logos, and service marks displayed on this document are registered in the United States [or other countries]. Any misuse of the trademarks is strictly prohibited and Tyco International Ltd. will aggressively enforce its intellec-
tual property rights to the fullest extent of the law, including pursuit of criminal prosecution wherever necessary. All trademarks not owned by Tyco International Ltd. are the property of their respective owners, and are used with permission or
allowed under applicable laws.
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales representative.
Comments
Access to Entry and Exit delays and Bell Time Out for the system.
Enables audible exit beeps from the keypad for the duration of exit delay.
Opening a Delay zone door after it has already been opened and closed during an exit
delay restarts the exit delay timer.
Function key: Forces the system to arm in Stay mode if the occupant does not exit the
premises after pressing the Away function key.
System times and audible exit beeps can be disabled when using the wireless key to
stay arm the system. When away arming, audible exit beeps can not be disabled.
Access to entry and exit delays and bell time out for the system
Note: Combined entry delay and communications delay (abort window) shall not
exceed 60s.
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross zone.
May be disabled by zone or zone type.
Access to the programmable delay before communicating alarms
Note: Combined entry delay and communications delay (abort window) shall not
exceed 60 seconds.
An audible tone is generated when an alarm is aborted during the abort window.
When this feature is enabled, selected user codes send a duress reporting code to the
central station when used to perform any function on the system. Section [019], option
[6] must be enabled.
Access to the communications cancel window. Minimum duration must be 5 minutes. Range: 005-255
Access to the reporting code for Alarm Canceled.
Enables cross zoning for entire system. Zones can be enabled for cross zoning via zone
attribute option 8 in sections [002][101] - [128].
Access to the programmable Cross Zone timer.
Access to the swinger shutdown limit for zone alarms
For all non-fire zones, shut down at 1 to 6 trips.
Access to swinger shutdown, transmission delay and cross zone attributes. Zone attri-
bute option 6 (Swinger Shutdown enabled) is ON.
Access to 24-Hr. Auto-verified Fire
Activates if Not restored within the specified time.
Access to the dialing sequence used to disable call waiting. Call waiting string can be
programmed in [034]
The system activates all keypad sounders, bells or sirens for 2 seconds and all keypad
lights turn on. Refer to user manual (part no. 29008365).
This mode is used to test each zone on the system for proper functionality.
Enables communication of zone alarms while walk test is active.
Access to the reporting codes for walk test start and end times.
Technical Support: 1-800-387-3630 (Can/US)
905-760-3000 (Intl.) www.dsc.com
firealarmresources.com
Range/Default
Requirement
Range:45- 255 seconds
Required
Default: 60 sec.
(programmable)
Individual keypads may be disabled
Allowed
Default: Enabled
Default: Enabled
Required
If no exit after full arm
Required
Default: Enabled
Default: Enabled
Allowed
Range: 30 sec. to 4 min.
Required
Default: 30 sec.
(programmable)
Default: Enabled
Required
Range: 00 - 45 sec.
Required
Default: 30 sees
(programmable)
Hard-coded ON
Required
Default: N
Required
Default: 005
A Cancel was transmitted
Required
Default: Enabled
Programming required
Required
Default: Disabled
Range: 000-255 sec.
Allowed
Default: 60 seconds
Default: 2 trips
Required
(programmable)
Non-police response zones
Allowed
Default: Enabled
Must choose zone type for applica-
Required
tion
Depends on user phone line
Required
Default: Disabled
Default: Disabled