Harvest TEC 436 Owner's Manual

25 gallon preservative applicators

Advertisement

Quick Links

OWNER'S MANUAL
Model 436
25 Gallon Preservative Applicators
Forage Harvester
436 – 11
5/22

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 436 and is the answer not in the manual?

Questions and answers

Summary of Contents for Harvest TEC 436

  • Page 1 OWNER’S MANUAL Model 436 25 Gallon Preservative Applicators Forage Harvester 436 – 11 5/22...
  • Page 2: Table Of Contents

    SELECTING TIPS AND SETTING PRESSURE CALIBRATION REMINDERS GENERAL CALIBRATION CHARTS ROUTINE MAINTENANCE WINTER STORAGE TROUBLE SHOOTING CHECKS PARTS BREAKDOWN 13-15 MODEL 436 BASE KIT MODEL 436 DRAIN/FILL KIT, & CONTROL BOX MODEL 436-SO INSTALLATION KIT NOTES WARRANTY AND LIABILITY BACK PAGE...
  • Page 3: Installation Kit Reference Chart

    For your convenience we have included a parts break down for the model 436 applicator. If something goes wrong bring this manual into the dealer so they can order the correct parts for you. Ordering the correct part number is very important.
  • Page 4: Installation Of The Applicator

    INSTALLATION OF APPLICATOR 1. INSTALLATION OF MOUNTING BRACKETS, TANK, AND DRAIN/FILL LINE Locate tank saddle legs (001-4442K & 001-4442D) as shown in figure 1. Fasten leg 001-4442D to 001-4442K with two 3/8 x 1 1/4” bolts, locks, flats, and nuts at point A. Secure 001-4442K to the baler using a 3/8 x 1 1/4”...
  • Page 5: Installation Of Mounting Brackets, Tank And Drain/Fill Line

    INSTALLATION OF MOUNTING BRACKETS, TANK, AND DRAIN/FILL LINE Locate the tank and saddle assembly. Position the tank and saddle so that the side tank fitting is towards the right side of the baler. The additional two weld-nuts on the saddle will then be facing forward as shown in point E on figure 4.
  • Page 6: Installation Of Spray Shield Assembly

    2. PLACEMENT OF SPRAY NOZZLE ASSEMBLY Locate the spray shield holder (001-4704E2) and spray shield (001-4703GK). Center the spray shield holder over the rotor. Clamp the bracket and drill two 7/16” holes point F on figure 6. Secure the bracket using two 3/8 x 1 1/4 bolts, locks, flats, and nuts. Tighten all hardware. Install the shield and secure using the two lynch pins (008-4576).
  • Page 7: Installation Of Controls

    OPERATION The 436 applicator is very simple to operate. After installing the applicator, fill the tank with 5 gallons of water. With control box connected to the applicator and the power cord hooked to the 12-volt battery we can start the test. First flip on the toggle switch. You might hear the buzzing of the motor.
  • Page 8: Calibration

    To find the exact number of pounds required, for a given hay moisture, refer to the label on the drum or contact the manufacture. Harvest Tec applicators come with the red, green, and blue sets of tips. If your chemical requires rates other than what these tips deliver you will need to purchase them through your dealer.
  • Page 9: Selecting Tips And Setting Pressure

    SELECTING TIPS AND SETTING PRESSURE Once you have determined your tons per hour and the amount of chemical needed for the moisture you are applying at, you can select your tips and determine your gauge settings. 1. Multiply the tons per hour by the amount of chemical required for the moisture you are applying at.
  • Page 10: General Calibration Charts

    GENERAL CALIBRATION CHART IN POUNDS PER HOUR Use the following chart for all applications that require pounds measurements. POUNDS PER HOUR WITH THREE NOZZLES INCLUDED IN KIT YELLOW GREEN BLUE BLACK 650067 XR11001 XR110015 XR11002 XR11004 CENTER 650033 650050 6501 6502 6503 OUTSIDE...
  • Page 11: Routine Maintenance

    2. Depending on the product being used, the system may need to be flushed with water at a regular interval (consult with manufacturer of the chemical.) If Harvest Tec product is being used, flushing is not necessary. 3. Although the pump can run dry, extended operation of a dry pump will increase wear. Watch the preservative level in the tank.
  • Page 12: Trouble Shooting Checks

    TROUBLE SHOOTING CHECKS PROBLEM POSSIBLE CAUSE SOLUTION Pump will not run. 1. Circuit breaker tripped 1. Check for short, low voltage, on electronic unit. and reset breaker. 2. Pump locked up. 2. Clean or rebuild pump if motor is OK. 3.
  • Page 13: Parts Breakdown

    HARVEST TEC MODEL 436 BASE KIT Ref# Description Part # Ref# Description Part # Tank Cap 005-9022C Tank Fitting 005-9100 Tank Cap Gasket 005-9022CG Tank mount bracket 001-4442K Tank Strap 001-4402 Tank support 001-4442KD Tank 005-9022 Mounting support 001-4442KE Saddle...
  • Page 14: Model 436 Drain/Fill Kit, & Control Box

    MODEL 436 DRAIN/FILL KIT, & CONTROL BOX Ref Description Part # Ref Description Part # Jiffy clip-large 008-9009 Female coupler 002-2204A Jiffy clip-small 008-9010 Straight fitting 003-A3434 Ball valve 002-2200 Elbow fitting 003-EL3434 Valve bracket 001-6702H Straight fitting 003-A1412 U-bolt – small...
  • Page 15: Model 436-So Installation Kit

    INSTALLATION KIT Ref Description Part # Description Part # Shield bracket 001-4704E2 Tip Kit (Complete) 030-9002 Spray shield 001-4703GK Plastic Box 008-9000 Hose 002-9001 Red Cap 004-1207B 003-TT14 Outside Tip (Red Set) 004-650050-SS Straight fitting 003-A1412 Inside Tip (Red Set) 004-XR11001VS Plug 003-F14...
  • Page 16: Notes

    Harvest Tec, LLC. Warranty and Liability Agreement. Harvest Tec, LLC. will repair or replace components that are found to be defective within 12 months from the date of manufacture. Under no circumstances does this warranty cover any components which in the opinion of Harvest Tec, LLC.

Table of Contents