Troubleshooting stepper motor driver
The normal operation is indicated by the ready LED. Only the green LED is lightning, the red
ones are switched off.
An error condition is indicated that one of the red LED is switched on. The ready signal is
deactivated and the error message "E__9" is shown on the display. Switch off the machine and
wait a few minutes (until no LED is lightning any longer).
Step
What is wrong
1a
No LED lightning
1b
1c
2a
LED over voltage
2b
2c
3a
LED
temperature
3b
4a
LED short circuit
4b
4c
4d
5
LED both
6
Double
dispensed
label
Release 11/2003
What could be the
reason
No supply voltage
Defective
disconnected cable
Nothing found
Wrong main voltage
selection
Transformer fault
Nothing found
over
Too
much
load
Ambient
temperature too high
Defective
disconnected cable
Wrong connection
Motor defective
Nothing found
High
temperature
and
short
circuit
detection on same
time
Wrong stepper mode Check
Page 43
How to check it
Measure
voltage
or
Check
connection
transformer to driver
board
Check
selector
Measure transformer
voltage should be
40V~ up to 55V~
heavy
Control rolls, brake
adjustment
Measure temperature
at
front
(<60°C)
or
Check
cable
screw terminal
Check
connections
on screw terminal
Check
all
above 3a – 4d
setting to 800 steps
Action
to
problem
supply
See trouble shooting
main supply
cable
Fasten
from
replace cables
Replace driver board
voltage
See trouble shooting
main supply
Change transformer
Replace driver board
Clean rolls, adjust
brake
Install
additional
plate
cooling
and
Fasten
replace cables
Correct cabling
Replace motor
Replace driver board
steps
jumper
Correct
position
solve
screws,
screws,
jumper