1.1 About the System

The PowerSeries Neo alarm panel is a feature-rich, scalable alarm
system designed for residential and light commercial use. The alarm
panel supports both hardwired and wireless devices. This section lists
the features of the alarm panel, available models, and compatible
devices.

1.1.1 Features

The following features are available on the PowerSeries Neo alarm
controller.
Zones
16, 32, 64, or 128 wireless zones supported and 8 hardwired
zones available on the controller
40 zone types and 14 programmable zone attributes
Up to 16 separate wireless keypads supported
Up to 32 separate wireless keys or panic pendants supported
Up to 95 separate proximity tags supported
Access Codes
Up to 98 access codes: one system master code, one installer
code, and one maintenance code
Programmable attributes for each user code (see page 20)
Programmable Outputs (PGMs)
Up to 4 programmable outputs (PGM) on the alarm controller
with 41 available options
148, 80, 38, 22 maximum programmable outputs
System Supervision Features
The PowerSeries Neo continuously monitors a number of possi-
ble trouble conditions and provides audible and visual indica-
tion at the keypad. Trouble conditions include:
• AC power failure
• Zone trouble
• Fire trouble
• Telephone line trouble
• Communicator trouble
• Low battery condition
• RF jam
• AUX power supply fault
• Failure to communicate
• Module fault (supervisory or tamper)
Additional Features
2-way wireless device support
Visual verification (images + audio)*
Proximity tag support
PGM scheduling
Quick arming
User, partition, module, zone and system labels
Programmable system loop response
Keypad and panel software versions viewable through keypad
Doorbell zone type
Low battery PGM type

1.1.2 Available Models

The following alarm controller models are available:
HS2016
HS2032
HS2064
HS2128
S e c t i o n 1 : I n t r o d u c t i o n
firealarmresources.com
Model Differences
The table below lists the features of each alarm system model.
Table 1-1 Model Differences
Features
HS2128 HS2064 HS2032 HS2016
Hardwired zones
128
Onboard zone inputs
8
Wireless zones
128
Partitions
8
Users
95
Onboard outputs
4
Max outputs
148
Keypads
16
Wireless keys
32
Wireless sirens
16
Wireless repeaters *
8
Proximity tags
94
Alt Comm. phone #'s
4
User-programmable
8
phone #'s
Lifesafety event buffer 1000
8-zone expander
15
HSM2108
Power supply
4
HSM2300
Power supply/high-
4
current output
expander HSM2204
8-output expander
16
HSM2208
2- way wireless inte-
1
gration module
Audio verification
1
PC5950
*For UL installations, 2 repeaters must be installed for proper signal
routing.
1
64
32
16
8
8
6
64
32
16
8
4
2
95
72
48
4
2
2
80
38
22
8
8
8
32
32
16
8
8
4
8
8
4
94
71
47
4
4
4
8
8
8
500
500
500
7
3
1
3
3
3
3
1
1
8
4
2
1
1
1
1
1
1