Fluke 5080A Manual page 15

Hide thumbs Also See for 5080A:
Table of Contents

Advertisement

Selection guides
Primary standards
Standard platinum resistance thermometers (SPRTs)
Model
RTPW
5681
25.5 Ω
5683
25.5 Ω
5684
0.25 Ω
5685
2.5 Ω
5698
25.5 Ω
5699
25.5 Ω
5686
25.5 Ω
ITS-90 fixed-point cells
Model
Description
Triple point of water cells
5901A-G
TPW Cell, 12 mm ID with handle, glass shell
5901A-Q
TPW Cell, 12 mm ID with handle, quartz shell
5901C-G
TPW Cell, 13.6 mm ID with handle, glass shell
5901C-Q
TPW Cell, 13.6 mm ID with handle, quartz shell
5901D-G
TPW Cell, 12 mm ID, glass shell
5901D-Q
TPW Cell, 12 mm ID, quartz shell
5901B-G
TPW Cell, mini, glass shell
Standard size fixed-point cells
5900E
TP mercury, SST
5904
Freezing point of indium
5905
Freezing point of tin
5906
Freezing point of zinc
5907
Freezing point of aluminum
5908
Freezing point of silver
5909
Freezing point of copper
5924
Open freezing point of indium
5925
Open freezing point of tin
5926
Open freezing point of zinc
5927A
Open freezing point of aluminum
5928
Open freezing point of silver
5929
Open freezing point of copper
5943
Melting point of gallium, SST
Mini triple point of water and fixed-point cells
5901B
Mini triple point of water
5914A
Mini freezing point of indium
5915A
Mini freezing point of tin
5916A
Mini freezing point of zinc
5917A
Mini freezing point of aluminum
5918A
Mini freezing point of silver
5919A
Mini freezing point of copper
5944
Mini freezing point of indium, metal cased
5945
Mini freezing point of tin, metal cased
5946
Mini freezing point of zinc, metal cased
5947
Mini freezing point of aluminum, metal cased
www.flukecal.com
Description
–200 °C to 670 °C, quartz sheath
–200 °C to 480 °C, quartz sheath
0 °C to 1070 °C, quartz sheath
0 °C to 1070 °C, quartz sheath
–200 °C to 670 °C, working standard, quartz sheath
–200 °C to 670 °C, high temperature, metal sheath
–260 °C to 232 °C, glass capsule
Temperature
0.01 °C
0.01 °C
0.01 °C
0.01 °C
0.01 °C
0.01 °C
0.01 °C
–38.8344 °C
156.5985 °C
231.928 °C
419.527 °C
660.323 °C
961.78 °C
1084.62 °C
156.5985 °C
231.928 °C
419.527 °C
660.323 °C
961.78 °C
1084.62 °C
29.7646 °C
0.01 °C
156.5985 °C
231.928 °C
419.527 °C
660.323 °C
961.78 °C
1084.62 °C
156.5985 °C
231.928 °C
419.527 °C
660.323 °C
Model
Features/use
Maintenance apparatus
7012
Maintains: triple point of water and gallium cells.
Comparisons: –10 °C to 110 °C.
7037
Maintains: triple point of water and gallium cells.
Comparisons: –40 °C to 110 °C.
7312
Maintains: two TPW cells. Compact size, runs quietly.
Comparisons: –5 °C to 110 °C.
7341
Maintains: triple point of mercury cell.
Comparisons: –45 °C to 150 °C.
9210
Maintains: mini triple point of water.
Comparisons: –10 °C to 125 °C.
9230
Maintains: stainless steel gallium cell.
Comparisons: 15 °C to 35 °C.
9260
Maintains: indium, tin, zinc, and aluminum cells.
Comparisons: 50 °C to 680 °C.
9114
Maintains: indium, tin, zinc, and aluminum cells.
Comparisons: 100 °C to 680 °C.
9115A
Maintains: aluminum and silver cells.
Comparisons: 550 °C to 1000 °C.
9116A
Maintains: aluminum, silver, gold, and copper cells.
Comparisons: 400 °C to 1100 °C.
9117
Anneals SPRTs, HTPRTs, and thermocouples to 1100 °C.
Protects them against contamination from metal ions.
Boiling point of liquid nitrogen
7196
Affordable substitute for a triple point of argon system.
Provides for low-temperature comparison calibrations at
approximately –196 °C with uncertainties of 2 mK.
Triple point of argon system
5960A
Lowest uncertainty for any commercially available triple
point of argon system.
Standard resistors
742A
Excellent performance without oil or air baths.
Values from 1 ohm to 19 megohm.
Temperature calibration
13