Fluke 5080A Manual page 14

Hide thumbs Also See for 5080A:
Table of Contents

Advertisement

Product highlights
6109A/7109A Portable Calibration Baths
Four times more calibration throughput
with twice the accuracy of Micro-Baths
and dry-block calibrators
Now there are portable calibration baths (6109A
and 7109A) designed with the process manufactur-
ing professional in mind. Process manufacturing
plants for pharmaceuticals, biotechnology, and
food production utilize many sanitary temperature
sensors that require regular calibration. Production
must stop during temperature sensor calibration.
Therefore, more calibration throughput means less
plant downtime.
The Fluke Calibration 6109A and 7109A Portable
Calibration Baths are liquid baths that let process
industry professionals calibrate four times more
sanitary sensors per batch in less time and with
twice the accuracy of other portable baths in this
class. Larger than micro baths, up to four tri-clamp
sanitary sensors fit easily into these baths for cali-
bration at ± 0.1 °C temperature display accuracy.
Calibrate up to four tri-clamp sanitary sensors at
the same time.
• Wide temperature ranges cover most process
applications
– 6109A: 35 °C to 250 °C
– 7109A: -25 °C to 140 °C
• Excellent display accuracy of ± 0.1 °C provides
4:1 test uncertainty ratio for critical applications
• Stainless steel casing withstands harsh
sterilizing chemicals and is rust proof
• NVLAP-accredited calibration included standard
Temperature calibration
12
1586A Super-DAQ Precision
Temperature Scanner
The most accurate, flexible temperature
data acquisition system
The 1586A is ideal for benchtop calibration of
temperature sensors in secondary calibration labs,
as well as temperature data acquisition applica-
tions in industries such as pharmaceutical, bio-
technology, aerospace, food and energy where
accurate temperature measurements are critical.
• Flexible configuration for the benchtop or
factory using the DAQ-STAQ Multiplexer or
internal High-Capacity Module
• Measure thermocouples, PRTs, thermistors, dc V,
dc I, and resistance
• Best-in-class temperature measurement
accuracy:
– PRTs: ± 0.005 °C (using DAQ-STAQ Multiplexer)
– Thermocouples: ± 0.29 °C (using DAQ-STAQ
Multiplexer and internal CJC for type K at 0 °C)
– Thermistors: ± 0.002 °C
• Connect up to 40 isolated inputs
• Scan speed of up to 10 channels per second
• Four modes of operation: Scan, Monitor,
Measure, DMM
• Real-time color trending—chart up to four
channels simultaneously
• Controls Fluke Calibration temperature sources
such as dry-wells, furnaces or Micro-Baths for
automated calibration routines
• MX + B scaling and channel offset zero function
• Built-in data security levels
www.flukecal.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

5502a5522a5730a9500b5322a6003a ... Show all

Table of Contents