Put the dipswitches nº4 of SW1 and SW2 to ON. The rest to OFF.
Turn on the power supply. The equipment transfer to bypass and beeps continuously. The microprocessor has been
recorded.
Shutdown the equipment.
Put the dipswitches of SW1 and SW2 to the wanted running position according to the table 1 and start up the equip-
ment again.
Note: This operation must be done the last one, because if the dipswitch 5 of SW1 is positioned to ON the equipment will start
up at lower voltage than the nominal again.
5.2.3.- Adjustment per phase.
P1.
Control PCB power supply. Factory preset. Do not touch.
P2.
Nominal output voltage adjustment.
P3.
Saving voltage adjustment.
Note 1: P2 and P3 can be adjusted with the equipment in operation. The adjustment of P3 when the equipment is running at
normal speedand we are reducing the saving voltage, must be done very slowly otherwise we will provoke a «Reset» of
the equipment .
Nota 2: If the default economy voltage is not apropiate, make the ajustment of the following form:
SW2-1 or SW2-3 at ON and make the ajustment witch the potenciometer P3.