Download Print this page

Graco 563918 Manual page 2

Mvb pump piston and seal repair kit

Advertisement

Installation
Installation
Pressure Relief Procedure
SKIN INJECTION HAZARD
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury such
as skin injection from pressurized fluid, follow the
Pressure Relief Procedure when you stop dispensing
and before cleaning, checking, or servicing the
equipment.
1. Disconnect power source.
2. Loosen outlet fitting or alternate outlet. (F
F
. 1
IG
Disassembly
Reference numbers used in the following instructions
refer to Parts, page 4.
1. Relieve pressure and remove pump from MVB
box.
2. Place pump upside down in a soft-jaw vise.
2
3. Depress piston guide (6) and remove self locking
ring (8e) and piston guide (6), ring retainer (8c), lock
washer (8g), piston retainer spring (1) and retention
spring (4) from the pump cylinder.
4. Remove pump from vise and turn it over. Replace
pump in soft-jaw vise with adjustment nut facing
upward.
5. Loosen set screw (8j) to relieve locking force on
cylinder and piston assembly. Removing the set
screw entirely is not necessary.
6. Remove pipe plug (8h). Unthread and remove
cylinder assembly (5).
NOTE:
Care should be taken when removing cylinder
. 1)
IG
assembly. Do not cut or damage o-rings
(7b - 7e).
Hold (a) (F
removing pipe plug.
F
. 2
IG
7. Inspect o-rings and backup rings (7b-7h) as
necessary. Replace damaged o-rings and
backup rings.
8. Remove pump cylinder from vise.
9. Place valve assembly (5) in vise and remove
indicator port adapter (a) (F
10. Remove valve assembly (5) from vise and remove
spring (3) and check ball (8a) from pump cylinder.
11. Inspect components and replace as needed.
. 2) with a 13/16 wrench when
IG
. 2).
IG
3A2603D

Advertisement

loading

This manual is also suitable for:

563919563920