Champion Global Power Equipment 100396 Operator's Manual

Champion Global Power Equipment 100396 Operator's Manual

3400w dual fuel electric start inverter generator

Advertisement

Quick Links

OPERATOR'S MANUAL
MODEL #100396
3400W DUAL FUEL ELECTRIC START
INVERTER GENERATOR
REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.com
or visit championpowerequipment.com
SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do
so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
Covered by one or more of the following U.S. Patent Numbers: 10,221,780, 16,191,503 and other U.S. and foreign patents pending.
REV 20220531
Champion Power Equipment, Inc., Santa Fe Springs, CA USA

Advertisement

Table of Contents
loading

Summary of Contents for Champion Global Power Equipment 100396

  • Page 1 OPERATOR'S MANUAL MODEL #100396 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com or visit championpowerequipment.com SAVE THESE INSTRUCTIONS. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury.
  • Page 2 CARBON MONOXIDE SAFETY: THE BIG PICTURE As the only safe way to use a portable generator, taking your generator outside is absolutely mandatory to keep your family safe from carbon monoxide. But there’s even more you can do. By educating yourself about all carbon monoxide risks, you’ll be better prepared to protect your family from this colorless, oderless threat.
  • Page 3: Table Of Contents

    TAbLE OF CONTENTS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR TAbLE OF CONTENTS Maintenance ..........Cleaning the Generator .......... Introduction ...........
  • Page 4: Introduction

    INTRODUCTION 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power Equipment The purpose of safety symbols is to attract your attention to possible dangers. The safety symbols, and their explanations, (CPE) product.
  • Page 5: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR IMPORTANT SAFETY INSTRUCTIONS DANGER  Generator produces powerful voltage. DANGER  DO NOT touch bare wires or receptacles. Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous gas. Breathing carbon monoxide will DO NOT use electrical cords that are worn, damaged or frayed.
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR WARNING CAUTION   Running engines produce heat. Severe burns can occur on Improper treatment or use of the generator can damage it, contact. Combustible material can catch fire on contact.
  • Page 7: Fuel Safety

    IMPORTANT SAFETY INSTRUCTIONS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Fuel Safety When adding or removing gasoline: DO NOT light or smoke cigarettes. DANGER  Turn the generator off and let cool for at least two minutes before removing the gasoline cap.
  • Page 8: Safety And Dataplate Labels

    IMPORTANT SAFETY INSTRUCTIONS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Safety and Dataplate Labels These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.
  • Page 9: Safety Symbols

    IMPORTANT SAFETY INSTRUCTIONS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 10 IMPORTANT SAFETY INSTRUCTIONS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR SYMBOL MEANING This product uses lithium-ion (Li-ion) batteries. Local, state, or federal laws may prohibit disposal of batteries in ordinary trash. Consult your local waste authority for information regarding available recycling and/or disposal options.
  • Page 11: Operation Symbols

    IMPORTANT SAFETY INSTRUCTIONS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 12: Controls And Features

    CONTROLS AND FEATURES 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference.
  • Page 13: Control Panel

    CONTROLS AND FEATURES 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Control Panel 1. Fuel Selector Switch – Used to select and turn on gasoline RECEPTACLES or LPG fuel source. 120V AC, 30A Locking (NEMA L5-30R) 2. LPG Hose Quick Connect Inlet.
  • Page 14: Parts Included

    CONTROLS AND FEATURES 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Parts Included Accessories Smart Charger ............LPG Hose with Regulator 0.7 m (2.3 ft.) ......RV Adapter Plug ............
  • Page 15: Assembly

    ASSEMbLY 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR ASSEMbLY Add Engine Oil Your generator requires some assembly. It must be properly WARNING  serviced with fuel and oil before operation. DO NOT attempt to crank or start the engine before it has been If you have any questions regarding the assembly of your properly filled with the recommended type and amount of oil.
  • Page 16: Add Fuel: Gasoline

    ASSEMbLY 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR 4. Using a funnel, add up to 20.3 fl. oz. (600 ml) of oil (not NOTICE  included) and replace oil fill cap/dipstick and secure cover. DO NOT OVERFILL. Synthetic oil may be used after the 5 hour initial break-in period.
  • Page 17: Add Fuel: Propane (Lpg)

    ASSEMbLY 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Add Fuel: Propane (LPG) CAUTION  DANGER Use unleaded gasoline with a minimum octane rating of 87  and an ethanol content of 10% or less by volume. NEVER place the LPG (liquefied petroleum gas) connector hose DO NOT light cigarettes or smoke when filling the tank.
  • Page 18: Grounding

    ASSEMbLY 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR A ground terminal connected to the panel of the generator has NOTICE  been provided (see Controls and Features for terminal location). For remote grounding, connect a length of heavy gauge –...
  • Page 19: Operation

    OPERATION 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR OPERATION WARNING  Do not expose to rain or use in damp locations. Generator Location Keep all objects a minimum of 5 feet (1.5m) away from the generator at all times. Heat from the muffler surface and WARNING ...
  • Page 20: Starting The Inverter

    OPERATION 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR 1. Make certain the generator is on a flat, level surface. GASOLINE 2. Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on.
  • Page 21: Propane (Lpg)

    OPERATION 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR 8. RECOIL START: Pull the starter cord slowly until resistance is 5. Push the battery switch to the “ON” position. felt and then pull rapidly. 6. Push the ignition switch to the “ON” position.
  • Page 22 OPERATION 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR 9. Do not over-choke. Allow the engine to warm up several 13. Pull the starter cord slowly until resistance is felt and then seconds before gradually pushing the choke to the “RUN”...
  • Page 23: Economy Control Switch

    100396 - 3400W Dual Fuel electric Start inverter Generator economy control Switch WarninG  The Economy Control switch can be activated in order to minimize Always remember to plug your appliances directly into the fuel consumption and noise while operating the unit during times...
  • Page 24: 12V Dc Regulated Automotive Style Outlet

    Never exceed the specified capacity when adding loads to the generator. Parallel Operation The Champion model 100396 is parallel ready and can be operated in parallel with another Champion unit to increase the 12V DC Regulated Automotive Style Outlet total available electrical power. A Champion parallel kit (optional The 12V DC outlet(s) can be used with supplied accessories and equipment) is required for parallel operation.
  • Page 25: Moving The Generator

    OPERATION 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Moving the Generator 5. Press the ignition switch to the “OFF” position. CAUTION  – NEVER lift or carry the generator using the folding handle. – NEVER tilt sideways while moving the generator.
  • Page 26: Overload Operation

    MAINTENANCE 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR To alleviate high altitude issues other than the natural power loss, CPE can provide a high altitude carburetor main jet. The alternative main jet and installation instructions can be obtained by contacting our Technical Support Team.
  • Page 27: Changing The Engine Oil

    MAINTENANCE 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR 1. Use a damp cloth to clean exterior surfaces of the generator. NOTICE  2. Use a soft bristle brush to remove dirt and oil. Once oil has been added, a visual check should show oil 3.
  • Page 28: Cleaning The Spark Arrestor

    MAINTENANCE 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Cleaning the Spark Arrestor Generator battery 1. Allow the engine to cool completely before servicing the spark This product is equipped with an automatic battery charging arrester. circuit. The battery will receive charging voltage when the engine is running.
  • Page 29: Storage

    STORAGE 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR STORAGE FIRST 5 HOURS (BREAK IN) — Change oil DANGER  Gasoline, gasoline vapors and liquid petroleum gas (LPG/ EVERY 50 HOURS OR ANNUALLY propane) are highly flammable and extremely explosive.
  • Page 30: Long Term Storage (Over 1 Year)

    StoraGe 100396 - 3400W Dual Fuel electric Start inverter Generator long term Storage (over 1 year) removing from Storage For storage over 1 year, the fuel tank and carburetor must be notice  completely drained of gasoline. If the generator has been improperly stored for a period 1.
  • Page 31: Specifications

    SPECIFICATIONS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR SPECIFICATIONS Oil Specifications DO NOT OVERFILL. Generator Specifications Type ..........*See following chart Generator Model ......... ..
  • Page 32: Temperature Specifications

    SPECIFICATIONS 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR Temperature Specifications Manual Starting Temperature Range (°F/°C) ........5 to 104/-15 to 40 Electric Starting Temperature Range (°F/°C)
  • Page 33: Troubleshooting

    TROUbLESHOOTING 100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Clean and adjust spark plug or replace. Fill crankcase to the proper level. Low oil level. Engine will not start.
  • Page 34 WARRANTY* Other Exclusions This warranty excludes: CHAMPION POWER EQUIPMENT – Cosmetic defects such as paint, decals, etc. 3 YEAR LIMITED WARRANTY – Wear items such as filter elements, o-rings, etc. Warranty Qualifications – Accessory parts such as starting batteries, and storage To register your product for warranty and FREE lifetime call center covers.
  • Page 35 CHAMPION POWER EQUIPMENT, INC. (CPE) AND THE UNITED STATES ENVIRONMENT PROTECTION AGENCY (U.S. EPA) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with U.S. EPA emission regulations. YOUR WARRANTY RIGHTS AND OBLIGATIONS: T T h h e U e US E S EP P A A A and CP P E a...
  • Page 36 EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1997 and later model year small off-road engines (SORE). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
  • Page 37 EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine) Systems covered by this Parts Description warranty Fuel Metering System Fuel regulator, Carburetor and internal parts Air Induction System Air cleaner, Intake manifold Ignition System Spark plug and parts, Magneto ignition system Exhaust System Exhaust manifold, catalytic converter...

Table of Contents