Champion Global Power Equipment 100402 Operator's Manual

Champion Global Power Equipment 100402 Operator's Manual

2000w dual fuel inverter generator

Advertisement

Quick Links

READ AND SAVE THIS MANUAL. This manual contains important safety precautions which should be read and understood before operating the product.
Failure to do so could result in serious injury. This manual should remain with the product.
Specifications, descriptions and illustrations in this manual are as accurate as known at the time of publication, but are subject to change without notice.
Covered by one or more of the following U.S. Patent Numbers: 10,641,187 and other U.S. and foreign patents pending.
REV 20211217
REGISTER YOUR PRODUCT ONLINE
at championpowerequipment.com
OPERATOR'S MANUAL
2000W Dual Fuel Inverter Generator
or visit championpowerequipment.com
Champion Power Equipment, Inc., Santa Fe Springs, CA USA
MODEL #100402

Advertisement

Table of Contents
loading

Summary of Contents for Champion Global Power Equipment 100402

  • Page 1 OPERATOR'S MANUAL MODEL #100402 2000W Dual Fuel Inverter Generator REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com or visit championpowerequipment.com READ AND SAVE THIS MANUAL. This manual contains important safety precautions which should be read and understood before operating the product. Failure to do so could result in serious injury. This manual should remain with the product.
  • Page 2: Table Of Contents

    TAbLE OF CONTENTS 100402 - 2000W DUAL FUEL INVERTER GENERATOR TAbLE OF CONTENTS Maintenance ..........
  • Page 3: Introduction

    INTRODUCTION 100402 - 2000W DUAL FUEL INVERTER GENERATOR INTRODUCTION SAFETY DEFINITIONS Congratulations on your purchase of a Champion Power The purpose of safety symbols is to attract your attention to Equipment (CPE) product. CPE designs, builds, and supports possible dangers. The safety symbols, and their explanations, all of our products to strict specifications and guidelines.
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS 100402 - 2000W DUAL FUEL INVERTER GENERATOR IMPORTANT SAFETY INSTRUCTIONS DANGER  Rotating parts can entangle hands, feet, hair, clothing and/ WARNING  or accessories. Traumatic amputation or severe laceration Cancer and Reproductive Harm – www.P65Warnings.ca.gov can result.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS 100402 - 2000W DUAL FUEL INVERTER GENERATOR WARNING CAUTION   Running engines produce heat. Severe burns can occur on Improper treatment or use of the generator can damage it, contact. Combustible material can catch fire on contact.
  • Page 6: Fuel Safety

    IMPORTANT SAFETY INSTRUCTIONS 100402 - 2000W DUAL FUEL INVERTER GENERATOR Fuel Safety Only fill or drain gasoline outdoors in a well-ventilated area. DO NOT pump gasoline directly into the generator at the gas DANGER  station. Always use an approved container to transfer the fuel to the generator.
  • Page 7: Safety Symbols

    IMPORTANT SAFETY INSTRUCTIONS 100402 - 2000W DUAL FUEL INVERTER GENERATOR Safety Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 8: Operation Symbols

    IMPORTANT SAFETY INSTRUCTIONS 100402 - 2000W DUAL FUEL INVERTER GENERATOR Operation Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 9: Quickstart Label Symbols

    IMPORTANT SAFETY INSTRUCTIONS 100402 - 2000W DUAL FUEL INVERTER GENERATOR Quickstart Label Symbols Some of the following symbols may be used on this product. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to more safely operate the product.
  • Page 10: Safety Labels

    IMPORTANT SAFETY INSTRUCTIONS 100402 - 2000W DUAL FUEL INVERTER GENERATOR Safety Labels These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a label comes off or becomes hard to read, contact Technical Support Team for possible replacement.
  • Page 11: Controls And Features

    CONTROLS AND FEATURES 100402 - 2000W DUAL FUEL INVERTER GENERATOR CONTROLS AND FEATURES Read this operator’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Generator 1.
  • Page 12: Power Panel

    CONTROLS AND FEATURES 100402 - 2000W DUAL FUEL INVERTER GENERATOR Power Panel 100% 00:00 REMAINING 1. Power Output – Percentage of available power from 5. LED Display generator being used. 5a. Flashing Blue – Total run time (first 5 seconds after 2.
  • Page 13: Outlet Panel

    CONTROLS AND FEATURES 100402 - 2000W DUAL FUEL INVERTER GENERATOR Outlet Panel 1. Ground Terminal – Consult an electrician for local RECEPTACLES grounding regulations. 12V DC, 8A (Regulated Automotive) 2. Circuit Breakers (Push Reset) – Protects the generator May be used to supply electrical power for against electrical overloads.
  • Page 14: Fcc Statement

    CONTROLS AND FEATURES 100402 - 2000W DUAL FUEL INVERTER GENERATOR FCC Statement Parts Included 1. This device complies with Part 15 of the FCC Rules. Accessories Operation is subject to the following two conditions: Oil Funnel ................1 1a. This device may not cause harmful interference.
  • Page 15: Assembly

    ASSEMbLY 100402 - 2000W DUAL FUEL INVERTER GENERATOR ASSEMbLY This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation. If you have any questions regarding the assembly of your generator, call our Technical Support Team at 1-877-338-0999.
  • Page 16: Add Fuel: Gasoline

    ASSEMbLY 100402 - 2000W DUAL FUEL INVERTER GENERATOR 3. Screw on the gasoline cap and wipe away any spilled fuel. NOTICE  CAUTION Weather will affect engine oil and engine performance.  Change the type of engine oil used based on weather Use unleaded gasoline with a minimum octane rating of 87 conditions to suit the engine needs.
  • Page 17: Add Fuel: Propane (Lpg)

    ASSEMbLY 100402 - 2000W DUAL FUEL INVERTER GENERATOR Add Fuel: Propane (LPG) CAUTION  1. Confirm the EZ Start dial is in the OFF position. Do not allow children to tamper or play with the LPG cylinder 2. If using a new propane cylinder, remove the plastic cap or hose connections.
  • Page 18: Operation

    OPERATION 100402 - 2000W DUAL FUEL INVERTER GENERATOR OPERATION – Electrical devices that require a grounded receptacle pin connection will not function if the receptacle ground pin is not functional. Generator Location Neutral Bonded to Frame* WARNING – Neutral circuit IS electrically connected to the frame/ground ...
  • Page 19: Surge Protection

    OPERATION 100402 - 2000W DUAL FUEL INVERTER GENERATOR 4. Turn EZ Start dial clockwise to the full “CHOKE” position. WARNING  Do not expose to rain or use in damp locations. Keep all objects a minimum of 5 feet (1.5m) away from the generator at all times.
  • Page 20: Starting The Engine: Propane (Lpg)

    OPERATION 100402 - 2000W DUAL FUEL INVERTER GENERATOR 6. Move the EZ Start dial to the “RUN” position. NOTICE  For gas starting in cold ambient <15°C (59°F): The choke must be in 100% of the “CHOKE” position for recoil start procedures.
  • Page 21: Connecting Electrical Loads

    OPERATION 100402 - 2000W DUAL FUEL INVERTER GENERATOR Connecting Electrical Loads 3. Identify the highest starting wattage of all devices identified in step 1. Add this number to the number Let the engine stabilize and warm up for a few minutes after calculated in step 2.
  • Page 22: Eco (Economy) Mode

    The 12V DC outlet(s) can be used with the supplied accessories Parallel Operation and other commercially available 12V DC automotive style The Champion model 100402 is parallel ready and can be plugs. The DC output is unregulated and can damage some operated in parallel with another Champion unit to increase products.
  • Page 23: Stopping The Engine

    MAINTENANCE 100402 - 2000W DUAL FUEL INVERTER GENERATOR MAINTENANCE Stopping the Engine Gasoline Make certain that the generator is kept clean and stored properly. Only operate the unit on a flat, level surface in a clean, 1. Turn off and unplug all electrical loads. Never start or stop dry operating environment.
  • Page 24: Changing The Engine Oil

    MAINTENANCE 100402 - 2000W DUAL FUEL INVERTER GENERATOR To prevent accidental starting, remove the spark plug wire 2. Remove the spark plug wire from the spark plug. before performing any service. Make sure spark plug wire end 3. Use a spark plug socket tool (not included), or a does not rest on any metal parts.
  • Page 25: Cleaning The Spark Arrestor

    MAINTENANCE 100402 - 2000W DUAL FUEL INVERTER GENERATOR Cleaning the Spark Arrestor Replacing Fuel Light batteries 1. Allow the engine to cool completely before servicing the 1. Use a small screwdriver to disassemble the upper cover. spark arrestor. 2. Remove the 4 screws holding the cover plate on the muffler side of the generator.
  • Page 26: Adjusting The Governor

    STORAGE 100402 - 2000W DUAL FUEL INVERTER GENERATOR FIRST 5 HOURS — Change oil EVERY 50 HOURS OR EVERY SEASON — Clean air filter — Change oil if operating under heavy load or in hot environments EVERY 100 HOURS OR EVERY SEASON 5.
  • Page 27: Long Term Storage (More Than 1 Year)

    STORAGE 100402 - 2000W DUAL FUEL INVERTER GENERATOR 1. Be sure all appliances are disconnected from the generator. 6. When gasoline stops flowing from the clear tube, rotate drain screw clockwise until tight. Properly dispose of 2. Add a properly formulated fuel stabilizer to the gasoline the drained gasoline according to local regulations or tank.
  • Page 28: Specifications

    SPECIFICATIONS 100402 - 2000W DUAL FUEL INVERTER GENERATOR SPECIFICATIONS Fuel Specifications Use regular unleaded gasoline with a minimum octane rating of Generator Specifications 87 and an ethanol content of 10% or less by volume. DO NOT USE E15 or E85. DO NOT OVERFILL.
  • Page 29: Troubleshooting

    TROUbLESHOOTING 100402 - 2000W DUAL FUEL INVERTER GENERATOR TROUbLESHOOTING Problem Cause Solution No fuel. Add fuel. Faulty spark plug. Replace spark plug. Generator will not start. Unit loaded during start up. Remove load from unit. Fill crankcase to the proper level.
  • Page 30: Warranty

    WARRANTY* 100402 - 2000W DUAL FUEL INVERTER GENERATOR WARRANTY* Other Exclusions This warranty excludes: CHAMPION POWER EQUIPMENT – Cosmetic defects such as paint, decals, etc. 3 YEAR LIMITED WARRANTY – Wear items such as filter elements, o-rings, etc. Warranty Qualifications –...
  • Page 31 CHAMPION POWER EQUIPMENT, INC. (CPE), THE UNITED STATES ENVIRONMENT PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) Exhaust and Evaporative emissions regulations.
  • Page 32 EXHAUST AND EVAPORATIVE EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Exhaust and Evaporative Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines).
  • Page 33 EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine) Systems covered by this Parts Description warranty Fuel Metering System Fuel regulator, Carburetor and internal parts Air Induction System Air cleaner, Intake manifold Ignition System Spark plug and parts, Magneto ignition system Exhaust System Exhaust manifold, catalytic converter...

Table of Contents