Press the NEXT key to select Option 11 and
press the Up or Down key to set the setpoint
differential.
Option
CANCEL
18

First Stage Differential

First stage temperature differential determines the
sensitivity of the thermostat. A lower differential
will cause the thermostat to cycle more often with
smaller temperature swings.
If the temperature differential between indoor
temperature and setpoint temperature is greater
than the first stage temperature differential, first
stage heating or cooling will be activated.
Press the NEXT key to select Option 11 and
press the Up or Down key to set the first stage
differential.
Option
CANCEL
19

Second Stage Differential

Second stage temperature differential
determines when the equipment advances from
first to second stage. If the temperature
differential between indoor temperature and
setpoint exceeds the second stage temperature
differential, the equipment activates second
stage heating or cooling.
Set To
NEXT
ENTER
Set To
NEXT
ENTER
Press the NEXT key to select Option 12 and the
Up or Down key to set the second stage
temperature differential. If the first stage
temperature differential is greater than third stage
temperature differential, first stage differential will
automatically be incremented.
Option
CANCEL
20

Third Stage Differential

Third stage temperature differential determines
when the equipment advances from second to
third stage. Setting the differential temperatures
the same for second stage and third stage turns
second and third stage on at the same time.
Press the NEXT key to select Option 13 and the
Up or Down key to set the third stage
temperature differential. The third stage
temperature differential cannot be set below the
second stage differential.
Option
CANCEL
21

Stage Timing

The Staging Override Time will turn on the next
stage even though the temperature differential has
not been reached.
Press the NEXT key to select Option 14 and the
Up or Down key to set the stage timing.