INSTALLATION
CAUTION: Do not install the fan from a single structure such as a perlin, truss, I-beam or bar joist.
For any questions or concerns regarding the building structure, consult a structural engineer.
Ensure the attachment point can support two times the weight of the fan and maximum torque of 75ft lbs. A
structural engineer should verify the structure prior to fan installation.
5 degrees of adjustment to accommodate an
unlevel beam.
16
STEP 1: MOUNTING
CRUSH HAZARD. To prevent SERIOUS INJURY or DEATH, ALWAYS mount fan directly
from building structure that can withstand double the installed fan weight.
RIGID MOUNT OVERVIEW
Tighten all 8 locking
nuts to 65 ft lbs with
3/4 inch socket and
torque wrench.
33.75 degrees of adjustment to accommodate
8/12 roof pitch.