im Vertrieb von
Appendix A • Programmer's Guide
Commands
Set Fade To Black
Fade Screen
Clear Fade To Black
Fade Screen
Unit Reset
Reset Unit
Query Software Version
Request Part Number
Request Information
Hph
•Vph
•Brt
↵
•Vrt
Example: Hph-112•Vph+009•Brt+000•Pkg1•Syn6•Mem1•Exe1•Mut0•Blk0•Fnc1•Hrt
↵
031.47•Vrt059.94
Where:
Horizontal Shift (Hph)
Vertical Shift (Vph)
Level (Brt)
Peaking (Pkg)
Sync Mode (Syn)
Memory Cycling (Mem)
Executive Mode (Exe)
Backlite Automode (Mut) =
Fade to Black (Blk)
Menu Language (Fnc)
Horizontal Scan Rate (Hrt) =
Vertical Scan Rate (Vrt)
Error Codes
Code
E10
E13
E14
www.camboard.de
Extron RGB 302/304 Universal Interface • User's Manual
CAMBOARD Electronics
ASCII
Hex
B
42
b
62
↵
Esc P 99
1B+50+39+39
Q/q
51/71
N/n
4E/6E
I/i
49/69
•Pkg
•Syn
•Mem
=
-112
=
+9
=
0
=
1
=
6 (Separate H & V with H = negative
=
1 (Enabled)
=
1 (On – Front Panel Locked Out)
0 (Off – Backlite stays lit)
=
0 (Off – Not faded)
=
1 (Menu language is English)
31.47 kHz
=
59.94 Hz
Description
Invalid command
Invalid value (too large)
Illegal command for this configuration (DIP Switch 1
is set ON for Digital Display Sync Processing and
Horizontal/Vertical Shift is requested)
Tel. 07131 911201
ce-info@camboard.de
Fax 07131 911203
Response
↵
Blk 1
↵
Blk 0
Updated
QVER
↵
N60-243-01
↵
N60-244-01
•Exe
•Mut
•Blk
and V = positive)
↵
↵
(for RGB 302)
(for RGB 304)
•Fnc
•Hrt
Page A-4