Electrical connections between internal and external unit
Before any work on the system, shut off the power at the breaker. Electrical connections between internal and external units must be perfor-
med using the three low voltage terminals: GND, A, B.
Connect «GND» on the terminal block of the internal unit with «GND» on the external terminal block.
Connect «A+» terminal block on the internal unit with «A» on the external terminal block.
Connect «B-» terminal block on the internal unit with «B» on the external terminal block.
EH1 EH1 ST1 ST1
B T
NOTE
It is strongly recommended to verify the presence of a surge protection device (SPD) on main power line and of circuit breakers
connected to the external and internal unit's control box
* See table of electrical connections
WARNING
After carrying out the connections between the indoor and outdoor unit, put back both panels of the respective units.