Technical data

Overview with
Overview with critical raw materials:
critical raw ma-
An overview of which critical raw materials are contained in this device can be
terials, year of
found at the following Internet address.
production of
www.fronius.com/en/about-fronius/sustainability.
the device
To calculate the year of production of the device:
-
-
-
-

Special Voltage

For devices designed for special voltages, the technical data on the rating plate
applies.
The following applies for all devices with a permitted grid voltage of up to 460 V:
The standard mains plug allows the user to operate with a grid voltage of up to
400 V. For grid voltages up to 460 V fit a mains plug permitted for such use or
install the mains supply directly.
Explanation of
The duty cycle (ED) is the period of a ten minute cycle in which the device may be
the term duty
operated at the stated power without overheating.
cycle
NOTE!
The ED values cited on the rating plate relate to an ambient temperature of
40 °C.
If the ambient temperature is higher, the ED or power must be lowered accord-
ingly.
Example: Welding with 150 A at 60% ED
-
-
-
124
Each device is provided with a serial number
The serial number consists of 8 digits - for example 28020099
The first two digits give the number from which the year of production of the
device can be calculated
This figure minus 11 gives the year of production
-
For example: Serial number = 28020065, calculation of the year of pro-
duction =
28
- 11 = 17, year of production = 2017
Welding phase = 60% of 10 mins = 6 mins
Cool-down phase = rest time = 4 mins
Following the cool-down phase, the cycle begins again.