Bag Stop; Clear Incomplete Bag - CUMMINS ALLISON CMX01 User Manual

Table of Contents

Advertisement

Bag Stop

The CMX10 has three stop levels. The active stop level type is defined in the "Settings" menu.
Batch 1: Individual stop number for every denomination
Batch 2: One stop number for all
Denominations Off: No stop
If Batch 1 or 2 is activated, it is possible to change the pre-defined stop during normal count.
Press "B" and enter with the numeric keypad a new stop between 0...99999. Press "M" to save
the new stop.
Alternative standard batch numbers (500, 1000, 2000, 5000, 10000) can be used by pressing "B"
several times.
B1
Count
Total
# 1
B
1000
0
1
#
➔ "B" ➔ enter new stop ➔ ➔ "M"
If you change a bag stop and the bag content is not zero, there will be a warning message "Do you
want to clear count and bag?" Press "1" (Yes) to clear the two counters or "2" (No) to count further
without clearing
Note: A steady stop in "Batch 1" must be entered in the Settings menu, option "Denom/Batch setting".

Clear Incomplete Bag

When you install an empty bag without a request from the CMX01, you must clear the Bag
content, otherwise, the counter will not start with "0", which may lead to an incorrect bag
stop. To delete the bag content, hold the "B" key for about 3 seconds.
10:45
0
0
0
2
?
CUMMINS ALLISON, A CPI BRAND 3350 Ridgeway Drive, Unit 3, Mississauga, Ontario L5L 5Z9