Fan
Type, Number of Set
Motor
Air-heat Exchanger
Refrigerant Control
Refrigerant Oil (Charged)
Refrigerant (Charged)
Running
Control Switch
Adjustment
Room Temperature
Safety Devices
Noise Level
1. Cooling capacities are based on indoor temperature of 27°C D.B.
(80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.), and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
ELECTRICAL DATA (60Hz)
ITEM / MODEL
Volts
Phase
Power Consumption
Running Current
Starting Current
Power Factor
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
4.7. CS-A34BB4P / CU-C34BBP8
Type
Input
kW
Rated
kW
Output
litre
kg
lbs
dB (A)
V
kW
Cool
A
Cool
A
%
Cool
Power source
Turbo fan-1
6-pole single phase
induction motor
0.15
0.08
Slit-fin type
Capillary tube
-
-
Wireless or Wired Remote
Control
Thermostat (Main Body)
Internal protector for compressor, Internal thermostat
fan motor, Crankcase heater, High pressure switch,
Hi 45
Me 42
CS-A34BB4P, CU-C34BBP7
Condition by JIS B 8615
31
Propeller fan
6-pole single phase
induction motor
Louvre-fin type
SONTEX200LT
Current transformer
Lo 40
220
3
3.30
5.70
39
88
AC, 3~220V, 60Hz
0.24
0.055 x 2
-
(4.2)
(11.1)
-
-
Hi 55