Noise Level
1. Cooling capacities are based on indoor temperature of 27°C D.B.
(80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B.
(68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°F D.B.),
6°C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL
Volts
Phase
Power Consumption
Running Current
Starting Current
Power Factor
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic
3.4. CS-A34BB4P / CU-A34BBP5
Cool
dB (A)
Heat
V
kW
Cool
Heat
A
Cool
Heat
A
%
Cool
Heat
Power source
Hi 39
Me 37
Hi 39
Me 37
CS-A28BB4P, CU-A28BBP8
Condition by JIS B 8615
380
3N
2.69
2.61
4.50
4.30
28
93
92
15
Lo 35
Lo 35
400
3N
2.69
2.61
4.45
4.25
29
89
89
AC, 3N~380V, 400V, 451V 50Hz
Hi 50
Hi 53
415
3N
2.69
2.61
4.40
4.20
30
87
87