Installation; Preliminary Checks - CAME V700E Installation Manual

Hide thumbs Also See for V700E:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 27
Size measurements
400 mm

Installation

The installation must be carried out by export, qualified personnel in total compliance with the norms in effect.

Preliminary checks

Before proceeding with the installation, it is necessary to:
• Make sure the area selected for the mounting of the base and for the unit itself is hazard free;
• Provide for a suitable omnipolar disconnection device with contacts more than 3 mm apart, and independent (sectioned off) power
supply;
• Make sure that any connections inside the case (that provide continuance to the protective circuit) be fitted with extra insulation as
compared to the other conductive parts inside;
• Make sure that the point where the gearmotor is fastened is protected from impact and that it is sturdy. The fastening must be carried
out using screws and/or rivets that are suitable for the type of surface;
Make sure that any connections inside the container (made for the continuity of the protection system) are provided with additional
insulation compared to the other conductive parts inside;
• Make sure that the door has a sturdy enough structure, that the hinges be in proper working order and that there is friction between
moving and fixed parts;
Cable list and minimun thickness
Connections
230V power supply
Flashing lamp
Photocell transmitters
Photocell receivers
24V power supply to accessories
Control and safety devices
Antenna connection
N.B.: if the cable length differs from that specified in the table, then you must determine the proper cable diameter in the basis of the actual
power draw by the connected devices and depending on the standards specified in CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw and
distances.
When connecting products other than those mentioned in this manual please see the documents provided with the products themselves.
3020 mm min. ÷ 4020 mm max.
Length of cable
Type of cable
1 < 10 m
3G x 1,5 mm
2 x 0,5 mm
FROR CEI 20-22
2 x 0,5 mm
CEI EN
4 x 0,5 mm
50267-2-1
2 x 0,5 mm
2 x 0,5 mm
RG58
Length of cable
10 < 20 m
2
2
3G x 2,5 mm
2
2
2 x 1 mm
2
2
2 x 0.5 mm
2
2
4 x 0,5 mm
2
2
2 x 0,5 mm
2
2
2 x 0,5 mm
max. 10 m
Length of cable
20 < 30 m
2
3G x 4 mm
2
2 x 1,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 1 mm
2
2 x 0,5 mm

Advertisement

Table of Contents
loading