Hazard Distance In Function Of Modifying Optics - Barco F400 Safety Manual

Hide thumbs Also See for F400:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 3
not less than 1 meter. Alternatively, in case the height of the separation barrier for the horizontal clearance is
at least 1 meter high then the horizontal clearance (SW) can be reduced to:
0 meter if the height of the hazard zone is minimum 2.5 meter.
0.1 meter if the height of the hazard zone is minimum 2.4 meter.
0.6 meter if the height of the hazard zone is minimum 2.2 meter.
LIPs for installations in unrestrained environment (concerts, ...) shall be installed at a height vertically above
the floor such that the bottom plane of the Hazard distance Zone shall be no lower than 3 meters above the
floor. Horizontal clearance to the hazard distance zone shall be not less than 2.5 meters. Any human access
horizontally to the Hazard Zone, if applicable, shall be restricted by barriers. If human access is possible in an
unsupervised environment, the horizontal or vertical clearances shall be increased to prevent exposure to the
hazard distance zone.
The LIP shall be installed by Barco or by a trained and Barco-authorized installer or shall only be transferred to
laser light show variance holders. This is applicable for dealers and distributors since they may need to install
the LIP (demo install) and/or they transfer (sell, rent, lease) the LIP. Dealers and distributors shall preserve
sales and installation records for a period of 5 years. Variance holders may currently hold a variance for
production of Class IIIB and IV laser light shows and/or for incorporating RG3 LIPs. Laser light show variance
for RG3 LIPs can be requested by mailing the application to RadHealthCustomerService@fda.hhs.gov.
The installation checklist for laser illuminated RG3 projectors must be fully completed after the installation.
The installation checklist can be downloaded from the Barco website. The installer shall preserve the checklist
for a period of 5 years.
Install one or more readily accessible controls to immediately terminate LIP projection light. The power input at
the projector side is considered as a reliable disconnect device. When required to switch off the projector,
disconnect the power cord at the projector side. In case the power input at the projector side is not accessible
(e. g. truss mount), the socket outlet supplying the projector shall be installed nearby the projector and be
easily accessible, or a readily accessible general disconnect device shall be incorporated in the fixed wiring.

1.5 Hazard distance in function of modifying optics

Hazard distance
Image 1–3
HD
Hazard Distance
TR
Throw Ratio
F400
Throw Ratio (TR)
Safety Information
R5914422 /00 F400
11

Advertisement

Chapters

Table of Contents
loading

Table of Contents