DVS Fast Charging System
Code
Fault Messages
134
Chrg Vdc Port A High
135
BMID A Vbat Too Low
136
BMID A Vbat Too High
137
Tbat Too High on Port A
138
BMID Comm Fail Port A
139
BMID Config Warning on
Port A
140
Not used
141
BMID Failure on Port A
142
BMID Temp Sensor Failure
on Port A
143
Vbat Mismatch on Port A
144
Battery Overdischarged on
Port A
145
Not used
164
Invalid Pilot on Port B
165
Chrg Vdc Port B Low
166
Chrg Vdc Port B High
167
BMID B Vbat Too Low
168
BMID B Vbat Too High
169
Tbat Too High on Port B
170
BMID Comm Fail Port B
171
BMID Config Warning on
Port B
172
Not used
173
BMID Failure on Port B
174
BMID Temp Sensor Failure
on Port B
175
Vbat Mismatch on Port B
176
Battery Overdischarged on
Port B
177
Not used
09910-W-03-02
Description
Battery voltage too high for
charger
Battery voltage too low for BMID
Battery voltage too high for BMID
Battery temp too high
BMID link lost after charge started
BMID not adequately configured
for charger usage
BMID reporting a critical failure
BMID temp sensor out of valid
range
BMID and terminal voltages don't
match
Battery excessively discharged
Battery connected with invalid
pilot circuit
Battery voltage too low for charger
Battery voltage too high for
charger
Battery voltage too low for BMID
Battery voltage too high for BMID
Battery temp too high
BMID link lost after charge started
BMID not adequately configured
for charger usage
BMID reporting a critical failure
BMID temp sensor out of valid
range
BMID and terminal voltages don't
match
Battery excessively discharged
Page 22 of 27
Operation and Maintenance Manual
Action
Webasto Charging Systems, Inc.
Z
L
L
H
F
M
-
G
G
KK
K
-
MM
Z
Z
L
L
H
F
M
-
G
G
KK
K
-

Advertisement

Table of Contents
loading

This manual is also suitable for: