[J] Bin Control Cycle; [K] Reset Switch - Hoshizaki DIM-40DE-HC Service Manual

Cube ice dispenser
Hide thumbs Also See for DIM-40DE-HC:
Table of Contents

Advertisement

[j] BIN CONTROL CYCLE

1) When the bin control switch stays on for more than 10 seconds, the bin control cycle
starts, and the icemaker stops. After the bin control switch stays off for more than 80
seconds, the bin control cycle ends and the icemaker restarts. (The hot gas valve
opens 30 seconds before the icemaker restarts.)
2) After the bin control cycle ends (or when the power supply is turned on), the water
pan starts to open (if the icemaker stopped while the water pan was closing).
3) If the bin control switch turns on while the water pan is opening after the power
supply is turned on (or after the reset switch is pressed), the bin control cycle does
not start.
When the water pan opens and the hall IC turns on, the bin control cycle starts after
10 seconds and the icemaker stops.

[k] RESET SWITCH

1) When the reset switch is pressed and released after the power supply is turned on,
the soft start is reset within 3 seconds and the water pan starts to open in the initial
cycle.
2) When the reset switch is pressed and released during operation (water pan opening
or closing, defrost or freeze cycle), the icemaker returns to the initial cycle within 3
seconds and the water pan starts to open.
* The above control is available because the water pan position is detected by the
hall IC not by a change switch.
3) When the reset switch is pressed and released while the icemaker is off in the bin
control cycle, the icemaker returns to the initial cycle within 3 seconds, the bin control
cycle ends, and the water pan starts to open.
4) When the reset switch is pressed and released while the icemaker is off with an error,
the icemaker returns to the initial cycle within 3 seconds, the error is reset, and the
water pan starts to open.
* When the icemaker returns to the initial cycle by the reset switch operation, the
water temperature is assumed to be 0°C (below 13°C), the freeze back up timer is
extended, the icemaking water supply time including additional water supply with
the water pan closed doubles and the number of freeze cycles becomes 0.